Neutron and photon radiation survey records have been used to evaluate and develop a neutron to photon (NP) ratio to reconstruct neutron doses to workers around Hanford's single pass reactors that operated from 1945 to 1972. A total of 5,773 paired neutron and photon measurements extracted from 57 boxes of survey records were used in the development of the NP ratio. The development of the NP ratio enables the use of the recorded dose from an individual's photon dosimeter badge to be used to estimate the unmonitored neutron dose. The Pearson rank correlation between the neutron and photon measurements was 0.71. The NP ratio best fit a lognormal distribution with a geometric mean (GM) of 0.8, a geometric standard deviation (GSD) of 2.95, and the upper 95 th % of this distribution was 4.75. An estimate of the neutron dose based on this NP ratio is considered bounding due to evidence that up to 70% of the total photon exposure received by workers around the single pass reactors occurs during shutdown maintenance and refueling activities when there is no significant neutron exposure. Thus when this NP ratio is applied to the total measured photon dose from an individual film badge dosimeter, the resulting neutron dose is considered bounded.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/HP.0b013e3181d4ee20 | DOI Listing |
Appl Radiat Isot
December 2024
Institute of Nuclear Techniques of Budapest University of Technology and Economics, Műegyetem Rkp 9, 1111, Budapest, Hungary.
This study presents a compact accelerator-driven neutron source design with a thermal neutron port and an epithermal neutron port for Boron Neutron Capture Therapy (BNCT), based on 10 mA 2.5 MeV protons bombarding on a 100 μm thick disc-shaped Li target with a diameter of 10 cm. The moderator consists of 2 parts, the epithermal neutron moderator and the thermal neutron moderator.
View Article and Find Full Text PDFFront Cell Neurosci
December 2024
Department of Molecular Biosciences, Centre for Radiation Protection Research, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden.
Introduction And Methods: Aiming to evaluate safety aspects of a recently proposed approach to target Alzheimer's disease, we mimicked a complex boron neutron capture therapy field using a mixed beam consisting of high- and low-linear energy transfer (LET) radiation, Am alpha particles (α) and/or X-ray radiation respectively, in human microglial (HMC3) cells.
Results: Acute exposure to 2 Gy X-rays induced the strongest response in the formation of γH2AX foci 30 min post irradiation, while α- and mixed beam-induced damage (α:X-ray = 3:1) sustained longer. Fractionation of the same total dose (0.
NPJ Microgravity
December 2024
University of Colorado Anschutz Medical Campus, Department of Obstetrics & Gynecology, Division of Reproductive Sciences, Aurora, CO, USA.
The effects of galactic cosmic radiation on reproductive physiology remain largely unknown. We determined the impact of near-continuous low-dose-rate Californium-252 neutron irradiation (1 mGy/day) as a space-relevant analog on litter size and number of resorptions at embryonic day (E) 12.5 (n = 19 radiated dams, n = 20 controls) and litter size, number of resorptions, fetal growth, and placental signaling and transcriptome (RNA sequencing) at E18.
View Article and Find Full Text PDFAppl Radiat Isot
December 2024
Department of Physics and Astronomy, McMaster University, Hamilton, ON L8S 4L8, Canada.
We report changes in Young's Modulus and breaking strength in compact costal porcine bone (Yorkshire breed, n = 9) subjected to escalating doses up to 4.0 Gy of fast neutrons, from a Li(p,n)Be reaction. The mean neutron energy was 233 keV.
View Article and Find Full Text PDFJ Radiat Res
December 2024
The Center for Peace, Hiroshima University, Higashisenda-machi 1-1-89, Naka-ku, Hiroshima 730-0053, Japan.
Radiobiological studies are ongoing to understand the consequences of internal exposure to neutron-activated radioactive microparticles, which were sprayed over experimental rats and mice. Special attention in these experiments is given to internal irradiation with radioactive microparticles with short-lived neutron-activated radionuclides 31Si (T1/2 = 2.62 h) and 56Mn (T1/2 = 2.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!