A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of different application durations of ER:YAG laser on intrapulpal temperature change during debonding. | LitMetric

Effects of different application durations of ER:YAG laser on intrapulpal temperature change during debonding.

Lasers Med Sci

Department of Orthodontics, Faculty of Dentistry, Yeditepe University, Bagdat Cad. No: 238, Göztepe, Istanbul, 34728, Turkey.

Published: November 2011

This study was done to determine the amount of lasing time required to remove ceramic brackets safely without causing intrapulpal damage by using Er:YAG laser with the scanning method. Part 1: 80 bovine mandibular incisors with ceramic brackets were randomly assigned into four groups of 20 as one control and three study groups. In the study groups, brackets were debonded after lasing for 3, 6, and 9 s, whereas debonding was performed without lasing in the control group. Shear bond strengths and ARI scores were also measured. Part 2: 30 human premolars with ceramic brackets were randomly divided into three groups of ten, as 3, 6, and 9 s of lasing durations. Intrapulpal temperature was measured at the same lasing times by a thermocouple. Statistically significant lower shear bond strengths were found in study groups compared to the control. A negative correlation was seen between the bond strengths and ARI scores in such a way that, as the shear bond strengths decreased, the ARI scores increased. Temperature increases for all the study groups were measured below the 5.5°C benchmark. All lasing times were effective for debonding without causing enamel tear outs or bracket failures. The temperature proportionally increased with the extension of the lasing duration. Six-second lasing by the scanning method using Er:YAG laser was found to be the most effective and safest way of removing the ceramic brackets without causing damage to the enamel and pulpal tissues.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10103-010-0796-7DOI Listing

Publication Analysis

Top Keywords

ceramic brackets
16
study groups
16
bond strengths
16
eryag laser
12
shear bond
12
ari scores
12
intrapulpal temperature
8
lasing
8
scanning method
8
brackets randomly
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!