A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of variation of MRI parameters on signal homogeneity: a qualitative analysis for ferrous benzoic xylenon orange gel. | LitMetric

Objective: This study focuses on the diverse effects of MRI parameters on image quality using widely available imaging pulse sequences.

Methods: A tissue equivalent gel system has been used for Magnetic Resonance Imaging by using Xylenol orange dye with Fricke-Benzoic solution which was formulated by Kelly R.G (1998). The gel system was radiated while using 6MV photons from Varian Clinic Linear Accelerator.

Results: The qualitative analysis include the effect of TR and TE on signal nonuniformity according to which the escalating repetition time gives a uniform signal having the average values calculated are 0.76%, 0.83%, 1.43% and 1.89% for the conventional spin echo (CSE), fast spin echo (FSE), gradient recalled echo (GRE) and fluid attenuated inversion recovery (FLAIR) respectively. FLAIR showed contradictory results due to longitudinal relaxation of the signal. This is because, at the longer value of inversion time (TI), the signal from simple fluids is nulled, thus reducing signal intensity.

Conclusion: The evaluation of signal uniformity for different pulse sequences demonstrates that the repetition time (TR) affects the signal homogeneity as it maintains image quality for CSE and FSE. However, a careful selection is required for FLAIR due to its sensitive behaviour for image uniformity.

Download full-text PDF

Source

Publication Analysis

Top Keywords

mri parameters
8
signal
8
signal homogeneity
8
qualitative analysis
8
image quality
8
gel system
8
repetition time
8
spin echo
8
time signal
8
effects variation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!