Background: Laparoscopic ultrasound (LUS) increases surgical safety by allowing the surgeon to see beyond the organ surface, by visualizing vascular structures and by improving surgical precision of tumor resection. A questionnaire-based survey was used to investigate the current use and future expectations of LUS technology.
Methods: A questionnaire consisting of 26 questions was distributed manually at four different conferences (60% at the European Association for Endoscopic Surgery (EAES) conference, Stockholm 2008). The answers were summarized with descriptive statistics and nonparametric tests at a significance level of 0.05.
Results: The questionnaire was answered by 177 surgeons from 40 different countries (85% from Europe). Of these surgeons, 43% use ultrasound during laparoscopic procedures. Generally, more LUS users are found at university hospitals than at general community hospitals. Surgeons use LUS primarily in procedures related to the liver (67% of the surgeons who use LUS), but LUS also is used in other procedures related to the pancreas, biliary tract, and colon. In a 5-year perspective, 82% of surgeons believe in an increased use of LUS, and 79% of surgeons also think that the use of LUS combined with navigation technology will increase and that the most important requirements for such a system are good image quality, easy interpretation, and a high degree of precision.
Conclusions: Although the surgeons believe LUS has advantages, only 43% of the respondents reported using it. The surveyed surgeons were largely positive toward an increased use of LUS in a 5-year perspective and believe that LUS combined with navigation technology will contribute to improving the surgical precision of tumor resection.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00464-010-1135-6 | DOI Listing |
J Thorac Dis
September 2024
Department of Vascular Surgery, Changhai Hospital, Naval Medical University, Shanghai, China.
Background: Thoracic endovascular aortic repair (TEVAR) with fenestrated surgeon-modified stent-grafts (f-SMSGs) is becoming an option for treating type B aortic dissection (TBAD) involving the aortic arch. This study aimed to evaluate the outcomes of this technique.
Methods: A retrospective multicenter study was conducted, involving consecutive patients from three medical centers in China who underwent TEVAR with f-SMSG for TBAD.
Int J Mol Sci
May 2024
Department of Gynaecology and Obstetrics, CERICSAL (CEntro di RIcerca Clinico SALentino), "Veris delli Ponti Hospital", 73020 Lecce, Italy.
In eutocic labor, the autonomic nervous system is dominated by the parasympathetic system, which ensures optimal blood flow to the uterus and placenta. This study is focused on the detection of the quantitative presence of catecholamine (C) neurofibers in the internal uterine orifice (IUO) and in the lower uterine segment (LUS) of the pregnant uterus, which could play a role in labor and delivery. A total of 102 women were enrolled before their submission to a scheduled cesarean section (CS); patients showed a singleton fetus in a cephalic presentation outside labor.
View Article and Find Full Text PDFHeliyon
May 2024
Department of Critical Care Medicine, Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China.
Background: Several studies have shown that bedside lung ultrasound findings in postanaesthesia care units (PACUs) and intensive care units (ICUs) correlate with postoperative pulmonary complications(PPCs) after noncardiac major surgery. However, it remains unclear whether lung ultrasound findings can be used as early predictors of PPCs in patients undergoing cardiac surgery. The main aim of our study was to evaluate the relationship between early postoperative point-of-care lung ultrasound findings and PPCs after cardiac surgery.
View Article and Find Full Text PDFJ Laparoendosc Adv Surg Tech A
July 2024
Department of Hepatobiliary Surgery, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Republic of China.
The treatment of choledocholithiasis with nondilated common bile duct (CBD) is a challenge for surgeons who often choose endoscopic retrograde cholangiopancreatography with laparoscopic cholecystectomy (LC) staging surgery instead of simultaneous laparoscopic CBD exploration with LC because of the small CBD diameter. This study aims to introduce and assess the clinical applicability of a technique we developed to identify and extract CBD stones using laparoscopic ultrasound (LUS). We retrospectively reviewed surgical procedures and clinical data of 13 patients who underwent LC and CBD exploration using LUS between May 2022 and August 2023.
View Article and Find Full Text PDFInt J Comput Assist Radiol Surg
July 2024
University Hospital of Clermont-Ferrand, Clermont-Ferrand, France.
Purpose: This research endeavors to improve tumor localization in minimally invasive surgeries, a challenging task primarily attributable to the absence of tactile feedback and limited visibility. The conventional solution uses laparoscopic ultrasound (LUS) which has a long learning curve and is operator-dependent.
Methods: The proposed approach involves augmenting LUS images onto laparoscopic images to improve the surgeon's ability to estimate tumor and internal organ anatomy.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!