AI Article Synopsis

  • The study aimed to compare how well standard echocardiography, contrast echocardiography, SPECT, and MRI measure left ventricular ejection fraction (EF) and end-diastolic volumes (EDV) in patients who had an acute STEMI.
  • All four imaging techniques were performed on the same day, revealing that while EF measurements were similar across methods, MRI consistently reported higher EDV compared to the others, likely due to different imaging approaches.
  • The findings suggest that echocardiography might be more cost-effective, but further investigation is necessary to understand the discrepancies in EDV readings.

Article Abstract

Aims: Magnetic resonance imaging (MRI) is often considered to be the gold standard in measuring left ventricular function and volumes. The aim of this study was to assess the agreements between standard echocardiography (standard echo), contrast echocardiography (contrast echo), single-photon emission computed tomography (SPECT), and MRI in the determination of left ventricular ejection fraction (EF) and end-diastolic volumes (EDV) in patients treated for acute ST-elevation myocardial infarction (STEMI).

Methods And Results: Standard echo, contrast echo, SPECT and MRI were performed on the same day, 3 months after STEMI in 150 patients participating in the NORwegian Study on District Treatment of ST-Elevation Myocardial Infarction (NORDISTEMI). Bland-Altman analysis of EF measured by all four imaging modalities showed generally low mean differences but wide limits of agreement. The mean EDV difference, however, was consistently higher when MRI was compared with standard echo (54.9 mL), contrast echo (41.7 mL) and SPECT (54.6 mL), and the limits of agreement were wider. The mean EDV differences between contrast echo vs. standard echo, SPECT vs. standard echo and contrast echo vs. SPECT were small.

Conclusion: Our data suggest that all four imaging modalities measured EF closely similar after STEMI as demonstrated by a very small bias. The limits of agreement were however wide. EDV measured by MRI was consistently higher when compared with the other methods which may be caused by different tracing-methods and imaging principles. As echocardiography is preferable from a cost-benefit point of view, further analysis would be needed to clarify the nature of such differences.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ejechocard/jeq069DOI Listing

Publication Analysis

Top Keywords

standard echo
20
contrast echo
20
left ventricular
12
st-elevation myocardial
12
myocardial infarction
12
echo contrast
12
echo spect
12
limits agreement
12
echo
10
ventricular function
8

Similar Publications

While current guidelines recommend R2* method as the first-line method for liver iron concentration (LIC) measurement, its diagnostic accuracy is debatable. A prior meta-analysis suggested limited accuracy of R2* method for identifying patients with iron overload. However, substantial advances in R2* method over the past decade may have improved its diagnostic performance.

View Article and Find Full Text PDF

High-Resolution Free-Breathing Chemical-Shift-Encoded MRI for Characterizing Lymph Nodes in the Upper Abdomen.

Invest Radiol

January 2025

From the Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands (I.T.M., M.C.M., S.Y., R.v.d.E., A.V., E.J.S., J.J.H., T.W.J.S.); and Department of Radiology, NYU Langone Health, New York, NY (T.K.B.).

Objectives: Accurate lymph node (LN) staging is crucial for managing upper abdominal cancers. Ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance imaging effectively distinguishes healthy and metastatic LNs through fat/water and -weighted imaging. However, respiratory motion artifacts complicate detection of abdominal LNs.

View Article and Find Full Text PDF

Weighted Echo State Graph Neural Networks Based on Robust and Epitaxial Film Memristors.

Adv Sci (Weinh)

January 2025

College of Physics Science & Technology, School of Life Sciences, Institute of Life Science and Green Development, Key Laboratory of Brain-Like Neuromorphic Devices and Systems of Hebei Province, Hebei University, Baoding, 071002, China.

Hardware system customized toward the demands of graph neural network learning would promote efficiency and strong temporal processing for graph-structured data. However, most amorphous/polycrystalline oxides-based memristors commonly have unstable conductance regulation due to random growth of conductive filaments. And graph neural networks based on robust and epitaxial film memristors can especially improve energy efficiency due to their high endurance and ultra-low power consumption.

View Article and Find Full Text PDF

Background: The pressure gradient between the ventricles and the subarachnoid space (transmantle pressure) is crucial for understanding CSF circulation and the pathogenesis of certain neurodegenerative diseases. This pressure can be approximated by the pressure difference across the aqueduct (ΔP). Currently, no dedicated platform exists for quantifying ΔP, and no research has been conducted on the impact of breathing on ΔP.

View Article and Find Full Text PDF

Objectives: To explore the reproducibility of the 1.5-T MR imaging (MRI)-based R2* method in measuring the liver iron concentration (LIC) across different MRI scanners, scan parameters, and postprocessing techniques.

Materials And Methods: We performed a systematic search of the PubMed, Embase, Medline, Cochrane Library, and Web of Science databases and identified studies that used the 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!