C2 laminar screws have become an increasingly used alternative method to C2 pedicle screw fixation. However, the outcome of this technique has not been thoroughly investigated. A total of 35 cases with upper cervical spinal instability undergoing C2 laminar screw fixation were reviewed. All cases had symptoms of atlantoaxial instability, such as craniocervical junction pain, and were fixed with the Vertex cervical internal fixation system. A total of 68 screws were placed and hybrid constructs (a C2 translaminar screw combined with a C2 pars screw) were incorporated in two patients. In this series, there were no intraoperative complications and no cases of neurological worsening or vascular injury from hardware placement. Computed tomographic scans demonstrated a partial dorsal laminar breach in ten patients. None of these resulted in neurological symptoms. None of the patients was found to have a breach of the ventral laminar cortex. All the C2 laminar screws fixations were performed successfully. There was no instability seen on the films with no evidence of hardware failure or screw loosening during the follow-up period in all patients. In conclusion, C2 laminar screw technique is straightforward and easily adopted; it can efficiently and reliably restore upper cervical stability. It is an alternative method to C2 pedicle screw fixation, especially in patients with unilateral occlusion of vertebral artery and pedicle deformity of C2.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2989209 | PMC |
http://dx.doi.org/10.1007/s00586-010-1447-1 | DOI Listing |
Micromachines (Basel)
January 2025
Faculty of Mechanical Engineering and Design, Kaunas University of Technology, 51424 Kaunas, Lithuania.
In recent years, microfluidics has emerged as an interdisciplinary field, receiving significant attention across various biomedical applications. Achieving a noticeable mixing of biofluids and biochemicals at laminar flow conditions is essential in numerous microfluidics systems. In this research work, a new kind of micromixer design integrated with an Archimedes screw is designed and investigated using numerical simulation and experimental approaches.
View Article and Find Full Text PDFBMC Musculoskelet Disord
November 2024
1Department of Spinal Surgery, Ningbo No.6 Hospital, NingBo, Zhejiang Province, 315040, China.
Background: To evaluate the feasibility of C2 laminar screw (C2LS) fixation assisted by double holes and to explore a novel method for judging its safe positioning.
Methods: The Digital Imaging in Communications format data of 25 C2 vertebrae specimens were obtained by computed tomography thin-slice scanning, and the data were imported into Mimics software for three-dimensional reconstruction. The bone cortex was removed at the starting and terminal midpoints of the lamina as the observation holes.
Bone Jt Open
September 2024
Department of Spine Surgery, Hospital for Special Surgery, New York, New York, USA.
Int J Surg Case Rep
November 2024
Department of Orthopaedics and Traumatology, Faculty of Medicine, Universitas Indonesia, Cipto Mangunkusumo Hospital, Jakarta, Indonesia.
J Orthop Case Rep
September 2024
Department of Spine Surgery, Yonsei Okay Hospital, Seoul, South Korea.
Introduction: Os-odontoideum is a rare condition described radiographically and clinically as a congenital anomaly of the second cervical vertebra (axis). It is a smooth, independent ossicle of variable size and shape separated from the base of a shortened odontoid process by an obvious gap, with no osseous connection to the body of C2.
Materials And Methods: This study reviewed the literature on OO to evaluate its etiology, clinical presentations, differential diagnosis, imaging modalities, and outcomes in the management of asymptomatic and symptomatic cases of Os Odontoideum.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!