Piezosurgery is an ultrasound instrument (24.7-29.5 kHz) that is able to cut the bone without necrosis and nonmineralized tissue damage. The aim of this work has been to determine the applicability and efficiency of the piezoelectric device in the excision of symptomatic ear osteomas. 10 patients affected by osteoma of the external auditory canal (EAC) (6 right, 4 left) were enrolled. Patients underwent excision of the EAC osteoma through a transcanal approach, with the piezoelectric device. Before and 6 months after surgery, all the patients underwent pure-tone audiometry, tympanometry, transient-evoked otoacoustic emissions, distortion product otoacoustic emissions, auditory brainstem response, and electronystamographic recording. The piezoelectric device provided excellent control without side effects on the adjacent structures of the external, middle and inner ear. The piezoelectric device is a new bony scalpel using the microvibrations at ultrasonic frequency so that soft tissue (nerve, vessel, dura mater, skin, etc.) will not be damaged even on accidental contact with the cutting tip. A feature of the piezoelectric device is its good manageability, which makes it easy for a well-trained otologic surgeon to create a straight osteotomy line: this renders the piezoelectric device suitable for bone surgery and for removal osteomas of the EAC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00405-010-1289-9 | DOI Listing |
Nat Commun
January 2025
State Key Laboratory of Advanced Design and Manufacturing Technology for Vehicle, College of Mechanical and Vehicle Engineering, Hunan University, Changsha, China.
Electrostriction is an important electro-mechanical property in poly (vinylidene fluoride) (PVDF) films, which describes the proportional relation between the electro-stimulated deformation and the square of the electric field. Generally, traditional methods to improve the electrostriction of PVDF either sacrifice other crystalline-related key properties or only influence minimal regions around the surface. Here, we design a unique electret structure to fully exploit the benefits of internal crystal in PVDF films.
View Article and Find Full Text PDFACS Nano
January 2025
School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing 210094, P. R. China.
Neural-electronic interfaces through delivering electroceuticals to lesions and modulating pathological endogenous electrical environments offer exciting opportunities to treat drug-refractory neurological disorders. Such an interface should ideally be compatible with the neural tissue and aggressive biofluid environment. Unfortunately, no interface specifically designed for the biofluid environments is available so far; instead, simply stacking an encapsulation layer on silicon-based substrates makes them susceptible to biofluid leakage, device malfunction, and foreign-body reactions.
View Article and Find Full Text PDFMicrosyst Nanoeng
January 2025
Department of Electrical Engineering (ESAT-MNS), KU Leuven, Belgium.
The use of bulk piezoelectric transducer arrays in medical imaging is a well-established technology that operates based on thickness mode piezoelectric vibration. Meanwhile, advancements in fabrication techniques have led to the emergence of micromachined alternatives, namely, piezoelectric micromachined ultrasound transducer (PMUT) and capacitive micromachined ultrasound transducer (CMUT). These devices operate in flexural mode using piezoelectric thin films and electrostatic forces, respectively.
View Article and Find Full Text PDFSci Adv
January 2025
NEST, Istituto Nanoscienze-CNR and Scuola Normale Superiore, I-56127 Pisa, Italy.
While piezoelectric sensing and energy-harvesting devices still largely rely on inorganic components, biocompatible and biodegradable piezoelectric materials, such as cellulose nanocrystals, might constitute optimal and sustainable building blocks for a variety of applications in electronics and transient implants. To this aim, however, effective methods are needed to position cellulose nanocrystals in large and high-performance architectures. Here, we report on scalable assemblies of cellulose nanocrystals in multilayered piezoelectric systems with exceptional response, for various application scopes.
View Article and Find Full Text PDFAesthet Surg J
January 2025
Careggi University Hospital, Florence, Italy.
Background: Preservation rhinoplasty, particularly dorsal preservation, has gained prominence with the advent of piezoelectric instruments, which minimize trauma and enhance precision in bone reshaping. This approach presents unique challenges, especially in closed techniques, where spatial limitations complicate the use of piezotomes.
Objectives: To evaluate outcomes of piezo-assisted preservation rhinoplasty using specialized instrumentation to enhance visibility, precision, and postoperative recovery in closed rhinoplasty procedures.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!