A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An in-depth study of long-term users of transcutaneous electrical nerve stimulation (TENS). Implications for clinical use of TENS. | LitMetric

An in-depth study of long-term users of transcutaneous electrical nerve stimulation (TENS). Implications for clinical use of TENS.

Pain

Clinical Psychopharmacology Unit, Department of Pharmacological Sciences, The Medical School, University of Newcastle upon Tyne, Newcastle upon Tyne NE2 4HH U.K.

Published: March 1991

This in-depth study examines the relationships between patient, stimulator and outcome variables in a large number of chronic pain patients utilising TENS on a long-term basis. 179 patients completed a TENS questionnaire designed to record age, sex, cause and site of pain and TENS treatment regime. Of these 179 patients, 107 attended our research unit for assessment of the electrical characteristics of TENS during self-administered treatment. Although a remarkable lack of correlation between patient, stimulator and outcome variables was found to exist, the analysis revealed much information of importance: 47% of patients found TENS reduced their pain by more than half; TENS analgesia was rapid both in onset (less than 0.5 h in 75% patients) and in offset (less than 0.5 h in 51% patients); one-third of patients utilised TENS for over 61 h/week; pulse frequencies between 1 and 70 Hz were utilised by 75% of patients; 44% of patients benefitted from burst mode stimulation. The clinical implications of these findings are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0304-3959(91)90089-GDOI Listing

Publication Analysis

Top Keywords

tens
9
patients
9
in-depth study
8
patient stimulator
8
stimulator outcome
8
outcome variables
8
179 patients
8
75% patients
8
study long-term
4
long-term users
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!