Objective: To investigate the influence of different sites of lateral suture fixation for stabilization of the cranial cruciate ligament (CCL) deficient stifle and different joint angles at time of tightening on suture tension.

Study Design: Controlled laboratory study.

Sample Population: Stifle joints (n=9) of dogs >or=20 kg.

Methods: After CCL transection, each stifle was stabilized using 12 combinations of 4 different methods of lateral suture stabilization (LSS) and 3 different joint angles at time of suture tightening. Load within the suture throughout a full range of passive motion (ROM) was measured for each combination using a custom made load cell.

Results: All 4 LSS methods had an increase in suture tension on stifle flexion. LSS with the suture looped around the lateral fabella and secured to the proximal aspect of the tibia through 2 parallel drill holes at the tibial crest had the least change in suture tension during ROM. Tightening the suture at 70 degrees joint angle resulted in a significant loss of suture tension on extension.

Conclusions: None of the LSS resulted in constant suture tension, questioning current recommendations regarding "isometric" points for lateral suture fixation. Tightening the suture with the stifle held in flexion may result in joint instability on extension.

Clinical Relevance: LSS as commonly performed is associated with a significant increase in suture tension on flexion of the stifle, potentially over-constraining the joint. Tightening should be performed with the stifle in slight extension rather than in flexion.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1532-950X.2010.00659.xDOI Listing

Publication Analysis

Top Keywords

suture tension
20
suture
16
lateral suture
16
suture fixation
12
tightening suture
12
joint angle
8
suture stabilization
8
stabilization cranial
8
cranial cruciate
8
cruciate ligament
8

Similar Publications

Background: Wound repair methods are commonly used in clinical practice, such as skin graft and flap repair, which can cause secondary injuries, and high costs. Many methods for skin stretching and repair have been reported domestically and internationally. However, their clinical use is limited owing to lack of equipment, complexity, and high costs.

View Article and Find Full Text PDF

"A Bridge-over-the Bar": A Novel Strategy to Prevent Paravalvular Regurgitation during Mitral Valve Replacement for Severe Mitral Annular Calcifications.

Ann Thorac Cardiovasc Surg

January 2025

Division of Pediatric and Adult Congenital Cardiac Surgery, Maria Fareri Children's Hospital, Department of Surgery, Westchester Medical Center, New York Medical College, Valhalla, NY, USA.

Mitral annular calcifications have been known to increase complexity during mitral valve replacement (MVR). Standard procedure requires decalcification followed by reconstruction of the mitral annulus prior to placing the prosthesis. While this is the ideal technique, it is not feasible in every patient due to the associated risks.

View Article and Find Full Text PDF

Introduction: Post-operative complications related to hardware, particularly symptoms caused by it, such as implant impingement, wire breakage, and skin infection are frequently reported following surgical management of patellar fractures with stainless steel wires. As a potential solution, some researchers have advocated for the use of non-absorbable sutures for fracture fixation. This study aims to investigate the clinical and radiological outcomes of patients treated with fiber taping as an alternative technique.

View Article and Find Full Text PDF

The traditional standard of care, tension band wire fixation modalities commonly used to treat non-comminuted olecranon fractures, are frequently associated with complications, with symptomatic hardware being the most common issue, often necessitating subsequent surgical procedures for hardware removal. We present a case of a young, active gentleman who sustained a simple olecranon fracture (Mayo type IIA) and underwent open reduction with the innovative all-suture non-metallic internal fixation procedure. We used a low-profile, cost-effective alternative fracture fixation technique, following the principles of pre-existing surgical techniques, while utilizing FiberWire sutures with biomechanical properties equivalent to, or possibly superior to, conventionally used metallic wires, thereby eliminating the need for additional surgical intervention.

View Article and Find Full Text PDF

The clinicopathologic conditions of the long head of the biceps tendon vary, encompassing tendinitis, peritendinous inflammation, hypertrophy, and partial or complete tears. These symptoms are typically linked with SLAP tears and instability of the long head of the biceps tendon, often resulting in partial displacement or complete dislocation. The choice between tenotomy and tenodesis depends on varied factors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!