Background: Research in hernia repair has targeted new atraumatic mesh fixation to reduce major complications such as chronic pain and adhesion formation. The efficacy and safety of two surgical adhesives, viz. Artiss® (FS, fibrin sealant containing 4 IU thrombin) and Bioglue® (AGG, bovine serum albumin/glutaraldehyde glue), were evaluated in this study. Primary study endpoints were tissue integration, dislocation, and adhesion formation. Foreign-body reaction formed the secondary study endpoint.

Methods: Twenty-four polypropylene meshes (VM, Vitamesh®) were randomized to four groups (n = 6): two groups of onlay hernia repair (two meshes per animal) with mesh fixation by FS (O-FS) or by AGG (O-AGG), and two groups of IPOM repair (one mesh per animal) with mesh fixation by four sutures and FS (I-FS) or AGG (I-AGG). Eighteen rats underwent surgery. Follow-up was 30 days. Tissue integration, dislocation, seroma formation, inflammation, adhesion formation, and foreign-body reaction were assessed.

Results: Meshes fixed with FS (O-FS, I-FS) showed good tissue integration. No dislocation, seroma formation, or macroscopic signs of inflammation were detectable. Adhesion formation of I-FS was significantly milder compared with I-AGG (P = 0.024). A moderate foreign-body reaction without active inflammation was seen histologically in O-FS and I-FS groups. Samples fixed with AGG (O-AGG, I-AGG) showed extensive scar formation. No dislocation and no seroma formation were observed. All of these samples showed moderate to severe signs of inflammation with abscess formation in the six meshes of O-AGG. Histology underlined these findings.

Conclusions: The fibrin sealant adhesive showed very good overall results of the primary and secondary outcome parameters. FS is a recommendable atraumatic fixation tool for the surgical onlay technique. AGG provides high adhesive strength, but shows low biocompatibility. Persisting active inflammation was seen in both the O-AGG and I-AGG groups, not favoring its use for these indications.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-010-1094-yDOI Listing

Publication Analysis

Top Keywords

mesh fixation
16
adhesion formation
16
fibrin sealant
12
tissue integration
12
integration dislocation
12
foreign-body reaction
12
dislocation seroma
12
seroma formation
12
formation
9
albumin/glutaraldehyde glue
8

Similar Publications

Acetabular fractures are rare fractures of the pelvis which usually result from trauma. Whilst data are reported on sexual and genitourinary function in those with pelvic fractures, less is known about those with isolated acetabulum fractures. This systematic review aimed to determine, first, the frequency of sexual and genitourinary dysfunction following isolated acetabulum fractures and, second, the nature of these complications.

View Article and Find Full Text PDF

Background: The sacroiliac joints (SIJ) are specialized articulations in the pelvis that allow load transfer between the upper and lower body. Traumatic pelvic disruption often requires surgical fixation of at least one of these joints. Subsequent SIJ pain is associated with asymmetries in joint laxity or stiffness.

View Article and Find Full Text PDF

Surgical strategies for recurrent hiatal hernia: three-point fundoplication fixation.

BMC Surg

January 2025

Center for Obesity and Hernia Surgery, Department of General Surgery, Huashan Hospital, Fudan University, Shanghai, 200040, China.

Background: The management of a recurrent (symptomatic) hiatal hernia remains controversial. This study aimed to review the outcomes of patients who underwent recurrent repair of hiatal hernias.

Methods: Thirteen patients who underwent recurrent hiatal hernia repairs at our hospital between 2018 and 2024 were reviewed retrospectively.

View Article and Find Full Text PDF

Objective: To evaluate the clinical efficacy and safety of ultrasound-guided rectus sheath block (RSB) in laparoscopic umbilical hernia repair with intraperitoneal onlay mesh (IPOM).

Methods: A total of 139 patients scheduled for laparoscopic umbilical hernia repair with IPOM were selected and randomly assigned to either the group receiving general anesthesia combined with bilateral rectus sheath block (Group GR, 71 patients) or the group receiving general anesthesia alone (Group G, 68 patients). We monitored the patients' heart rate (HR) and mean arterial pressure (MAP) at four time points: before anesthesia induction (T1), at the start of surgery (T2), during mesh fixation (T3), and upon removal of the laryngeal mask (T4).

View Article and Find Full Text PDF

The reliable engraftment of skin grafts into areas with complex shapes can be challenging. Here, we report a case of successful fixation of a genital skin graft using negative pressure wound therapy (NPWT) with RENASYS Cotton Filler. A 44-year-old male with no relevant medical history underwent split-thickness skin grafting for a genital skin defect caused by Fournier's gangrene.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!