Effect of blast trauma and corneal foreign bodies on visual performance.

Optom Vis Sci

Ophthalmology Service, Walter Reed Army Medical Center, Washington, District of Columbia 20307-5001, USA.

Published: August 2010

Purpose: To evaluate the effect of non-penetrating corneal foreign bodies secondary to explosive blasts on the visual performance of soldiers.

Methods: In a prospective, non-interventional study subjective visual performance and objective optical quality of 11 injured eyes with retained corneal foreign bodies were compared with that of 11 normal controls. Visual performance measures consisted of best spectacle-corrected high-contrast visual acuity (HCVA), low-contrast (5%) visual acuity (LCVA), and contrast sensitivity (CS). LCVA was evaluated in two luminance levels (photopic and mesopic) and two glare conditions (with and without glare). Acuity measurements were scored using logMAR notation. Objective optical quality was assessed comparing total root mean square wavefront error (WFE) and percent higher order aberrations. Modulation transfer functions calculated from the wavefront maps were used to predict the results of the psychophysical contrast testing.

Results: HCVA of injured eyes (M = -0.03) did not differ significantly (t(20) = 1.56, p = 0.13) when compared with controls (M = -0.09). However, visual performance of injured eyes (M = 0.33) was significantly worse than control eyes (M = 0.11) on photopic LCVA (t(20) = 4.16, p < 0.001), mesopic LCVA(M = 0.44 vs. M = 0.21, t(20) = 3.85, p = 0.001), mesopic LCVA with glare (M = 0.49 vs. M = 0.21, t(20) = 3.66, p = 0.002), and small letter CS (M = 0.25 vs. M = 0.90, t(20) = -6.6, p < 0.001). For a 6-mm pupil, mean absolute WFE attributed to higher order aberrations for the injured eyes was 0.86 microm and 0.59 microm for the control eyes. This difference was significant (t(20) = -2.15, p = 0.044).

Conclusions: Although HCVA was no different than the normal controls, visual performance of the injured eyes was significantly worse in terms of LCVA and CS. On average, visual performance can be broadly predicted by the modulation transfer function derived from the subjects' wavefront aberration map.

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0b013e3181e61bc0DOI Listing

Publication Analysis

Top Keywords

visual performance
28
injured eyes
20
corneal foreign
12
foreign bodies
12
visual
9
objective optical
8
optical quality
8
normal controls
8
controls visual
8
visual acuity
8

Similar Publications

Comparison of Recruitment Method on Clinical Outcomes Following Cervical Disc Arthroplasty.

Spine (Phila Pa 1976)

January 2025

Indiana Spine Group Location of investigation Indiana Spine Group, 13225 N. Meridian Street, Carmel, IN 46032.

Study Design: Retrospective cohort.

Objective: To compare the clinical outcomes of trial versus standard clinical practice (SCP) patients following cervical disc arthroplasty (CDA).

Background: CDA is hypothesized to reduce the shear strain and related complications resulting from fusion procedures.

View Article and Find Full Text PDF

Background/purpose: Computer-assisted implant surgery (CAIS) is increasingly performed to reduce deviations in implant position. Dynamic CAIS or navigation systems provide instant display of implant drilling instruments and patient positions directly on the computer monitor. Augmented reality (AR) technology allows operators to visualize real-time information projected onto the lenses of AR glasses.

View Article and Find Full Text PDF

Objective: Previous studies on the efficacy of methotrexate in people with hand osteoarthritis (OA) have shown conflicting results. The MERINO trial aims to investigate the efficacy and safety of methotrexate in people with painful inflammatory erosive hand OA.

Design: In total 163 participants with erosive hand OA, synovitis by ultrasound, and finger joint pain of 40-80 ​mm on a visual analogue scale (VAS) will be recruited from a rheumatology outpatient clinic.

View Article and Find Full Text PDF

An empirical study of LLaMA3 quantization: from LLMs to MLLMs.

Vis Intell

December 2024

Department of Information Technology and Electrical Engineering, ETH Zurich, Sternwartstrasse 7, Zürich, Switzerland.

The LLaMA family, a collection of foundation language models ranging from 7B to 65B parameters, has become one of the most powerful open-source large language models (LLMs) and the popular LLM backbone of multi-modal large language models (MLLMs), widely used in computer vision and natural language understanding tasks. In particular, LLaMA3 models have recently been released and have achieved impressive performance in various domains with super-large scale pre-training on over 15T tokens of data. Given the wide application of low-bit quantization for LLMs in resource-constrained scenarios, we explore LLaMA3's capabilities when quantized to low bit-width.

View Article and Find Full Text PDF

Background And Aim: It is important for endoscopist to diagnose the lesion redness. In this study, we focused on the redness of duodenal bulb. We objectively analyzed the changes in redness of the duodenal bulb using linked color imaging (LCI) with chromatic indicators.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!