Purpose: To evaluate the biomechanical properties of 3 anterior cruciate ligament (ACL) reconstruction femoral fixation devices in a porcine model with implantation on both the lateral femoral cortex and the anterior femoral cortex.

Methods: ACL reconstructions with an 8-mm porcine tendon graft were performed on 48 porcine femurs with the EndoButton CL (Smith & Nephew, Andover, MA), ToggleLoc with ZipLoop technology (Biomet Sports Medicine, Warsaw, IN), or EZLoc (Biomet Sports Medicine). In 8 specimens for each implant, the femoral tunnel was drilled from the 10:30 surgical position out the lateral cortex. In another 8 specimens for each implant, the tunnel was drilled from the 10:30 position to a standardized anterior femoral surface. Cyclic testing was performed on an MTS testing machine (MTS, Eden Prairie, MN) from 50 N to 450 N for 2,000 cycles, followed by load-to-failure testing in specimens that survived. The cortical thickness and location of the implant exit were recorded.

Results: In the lateral femur group, 0 of the EZLoc devices, 2 of the ToggleLoc devices, and 3 of the EndoButtons completed cyclic testing. In the anterior femur group, 1 of the EZLoc devices, 5 of the ToggleLoc devices, and 5 of the EndoButtons completed cyclic testing (P = .012). In the anterior femur group, the ToggleLoc exhibited higher 2,000-cycle elongation (5.46 +/- 1 mm) than the EndoButton (3.55 +/- 0.6 mm) (P = .005). The EndoButton showed a higher first failure load (1,190.9 +/- 150.0 N) than the ToggleLoc (912.6 +/- 82.4 N) (P = .007). The anterior cortex (1.4 mm) was thinner than the lateral cortex (1.7 mm) (P = .0002).

Conclusions: The EndoButton provided the strongest ACL femoral fixation with significantly less graft-implant elongation and significantly higher failure loads. It was also shown in a porcine model that implants on the anterior cortical surface perform better than those on the lateral surface. Increased cortical thickness, in the range tested, was not associated with improved implant performance in the porcine model.

Clinical Relevance: The EndoButton provided the best ACL femoral fixation of the devices tested.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arthro.2009.10.015DOI Listing

Publication Analysis

Top Keywords

femoral fixation
16
fixation devices
12
lateral cortex
12
cyclic testing
12
femur group
12
anterior
9
anterior cruciate
8
cruciate ligament
8
anterior cortex
8
porcine model
8

Similar Publications

Objective: The aim of this study was to evaluate whether the locking femoral neck plate (LFNP) can be an alternative fixation method to the cannulated screws with a medial buttress plate. For this purpose, we compared biomechanically the LFNP and cannulated screws with or without a medial buttress plate in Pauwels type 3 femoral neck fractures.

Methods: A vertical fracture model was created at an 80-degree angle to the femoral neck in 28 synthetic bone models.

View Article and Find Full Text PDF

This study introduces a novel anchor-type proximal femoral nail (AT-PFN) to improve the bone-fixation integrity over the standard screw-type nail (SST-PFN). Quasi-static incremental cyclic load test was performed to investigate load-displacement, cumulative deformation energy, time-strain, and backbone curves. The finite element analysis (FEA) was implemented to identify the stress and strain distributions.

View Article and Find Full Text PDF

Objective: To evaluate the efficacy of supra-inguinal fascia iliaca compartment block (S-FICB) in patients undergoing proximal femoral nail antirotation (PFNA) internal fixation surgery for intertrochanteric fracture (ITF).

Methods: Retrospective analysis of 95 patients with ITF undergoing PFNA internal fixation surgery in the First People's Hospital of Yong Kang from March 2021 to August 2023 was performed. Among them, 49 patients received general anesthesia (GA; GA group) and 46 patients received S-FICB combined with general anesthesia (S-FICB group).

View Article and Find Full Text PDF

Background: Gravid females with pelvic fractures are rarely encountered by the orthopaedic trauma surgeon. The initial injury can be detrimental to the pregnant patient, but an unnecessary "second hit" from surgery could also contribute to the outcome of the fetus. Understanding the surgical risks for this unique patient population requires knowledge about the negative effects of anesthesia, surgical exposures, and radiation.

View Article and Find Full Text PDF

Background: A population-based study delineating the epidemiologic, clinical, and treatment characteristics of femoral neck fractures (FNFs) in elderly patients has not yet been conducted in Turkey. In this nationwide study, the epidemiologic, clinical, and treatment characteristics of patients aged ⩾65 years with FNFs who underwent osteosynthesis, hemiarthroplasty (HA), or total hip arthroplasty (THA) were examined.

Methods: Patients aged ⩾65 years with FNFs were identified in this retrospective, nationwide study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!