A hallmark of cardiac tamponade is pulsus paradoxus. However, the exact mechanism of pulsus paradoxus and the relation of left and right ventricular ejection dynamics remain controversial, with some studies suggesting an inverse relation in ventricular filling and ejection and others citing a more important role for the effects of right heart ejection dynamics delayed by transit through the pulmonary artery bed. To specifically reexamine this issue, six sedated but spontaneously breathing dogs were studied during experimental cardiac tamponade with use of extensive hemodynamic instrumentation and Doppler methods. During cardiac tamponade, left ventricular systolic pressure decreased from 125.8 +/- 12.1 to 81.7 +/- 26.7 mm Hg (p less than 0.01) and cardiac output from 5.86 +/- 1.48 to 2.34 +/- 0.98 liters/min (p less than 0.001); mean pericardial pressure increased from -1.2 +/- 0.8 to 10.5 +/- 3 mm Hg (p less than 0.001) and pulsus paradoxus from 4.3 +/- 1.6 to 10.7 +/- 1.2 mm Hg (p less than 0.001) compared with baseline values. An inverse relation in left and right ventricular ejection dynamics that was very close to 180 degrees out of phase was seen throughout the respiratory cycle in multiple hemodynamic and Doppler variables including peak systolic pressures, aortic and pulmonary flow velocities and ventricular ejection times. Simultaneous recording of the transmitral pressure gradient provided indirect evidence that the ventricular ejection dynamics were directly related to changes in ventricular filling. However, the magnitude of ventricular pressure or output flow velocity for each respiratory cycle was variable, depending on the exact timing of filling and ejection in relation to the phase of respiration. Variation in left ventricular output due to changes in right ventricular output delayed by transit through the pulmonary vasculature was not recognized in any animal. It is concluded that in spontaneously breathing dogs with acute cardiac tamponade, peak ventricular pressures, ventricular ejection times and pulmonary and aortic flow velocities have an inverse relation that is very close to 180 degrees out of phase.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0735-1097(10)80246-3DOI Listing

Publication Analysis

Top Keywords

cardiac tamponade
20
ejection dynamics
20
ventricular ejection
20
left ventricular
16
relation left
12
pulsus paradoxus
12
ventricular
12
inverse relation
12
ejection
9
experimental cardiac
8

Similar Publications

Comparing pulsed field ablation with very high-power and high-power short-duration radiofrequency ablation for atrial fibrillation: a systematic review and meta-analysis.

J Interv Card Electrophysiol

December 2024

Section of Electrophysiology, Division of Cardiology, Department of Medicine, Rush University Medical Center, 1717 W Congress Pkwy/Suite 317 Kellogg, Chicago, IL, 60612, USA.

Background: Catheter ablation is a key treatment for atrial fibrillation (AF), with high-power, very high-power short-duration and pulsed field ablation (PFA) being efficient options. However, direct comparisons between these techniques are lacking.

Objective: We performed a systematic review and meta-analysis, which included predominantly observational studies (four retrospective and one prospective study), to compare PFA and High-power short-duration (HPSD) and very high-power short-duration (vHPSD) radiofrequency (RF) ablation in patients with AF.

View Article and Find Full Text PDF

A 43-year-old woman presented with dyspnea and cough, initially misdiagnosed as respiratory syncytial virus. Persistent symptoms led to pulmonary thromboembolism treatment, but worsening issues revealed recurrent pericardial effusion. Imaging and biopsy confirmed pulmonary artery intimal sarcoma, mimicking thromboembolism, and autoimmune disease, underscoring diagnostic challenges.

View Article and Find Full Text PDF

Background Combining left atrial appendage closure with catheter ablation (LAACCA) has been proposed as a potential approach to improving outcomes by simultaneously addressing arrhythmia and reducing stroke risk. This study compares the in-hospital outcomes of LAACCA vs. catheter ablation (CA) alone for atrial fibrillation (AFib) in patients with heart failure with reduced ejection fraction (HFrEF).

View Article and Find Full Text PDF

The patient an 85-year-old female resided in a care facility where she maintained an independent daily activity level. She was discovered hunched over a table in her room, displaying reduced responsiveness and prompting an emergency call. Initially, her blood pressure was within 60 mmHg, and she was transported by ambulance to our hospital.

View Article and Find Full Text PDF

Background: Delayed lead perforation is a rare complication of cardiac implantable electronic device (CIED). Clinical presentations range from completely asymptomatic to pericardial tamponade. Surgical lead extraction is recommended and transvenous lead extraction (TLE) with surgical backup is an alternative method.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!