Muscle tissue oxygenation and VEGF in VO-matched vibration and squatting exercise.

Clin Physiol Funct Imaging

Institute for Biomedical Research into Human Movement and Health, Manchester Metropolitan University, Manchester, UK.

Published: July 2010

Exposure to vibration has traditionally been associated with compromised perfusion. This study investigated whether blood supply during whole body vibration (WBV), as an exercise modality, is in proportion to the metabolic demand by the contracting musculature. As a secondary aim, serum levels of vascular endothelial growth factor (VEGF) were assessed. Ten young healthy males performed WBV and dynamic shallow squatting (Squat) exercise at comparable levels of oxygen uptake for 3 min. Changes in oxygenated, deoxygenated and total haemoglobin (O(2)Hb, HHb and tHb, respectively) along with tissue oxygenation index (TOI) were measured continuously before, during and after the exercise by near-infrared spectroscopy (NIRS, Portamon, Artinis Medical Systems, Zetten, The Netherlands). Vascular endothelial growth factor-A blood levels before and after exercise were assessed by ELISA. Oxygen uptake was comparable in Squat and WBV (11.4 and 10.7 ml kg(-1) min(-1)), respectively, P = 0.49), as were all other cardiopulmonary variables. Near-infrared spectroscopy data were found to be non-stationary during and shortly after WBV, but stationary in Squat. There was an increase in O(2)Hb and TOI, and a decrease in HHb during the first 30 s of WBV, but no significant change was observed during Squat. No group difference was found in VEGF serum levels. These results suggest that oxygen supply during WBV is sufficient, and oxygenation is even enhanced during the first approximately 30 s. Most likely, the transient response is because of local vascular regulatory mechanisms and due to muscle contraction mechanics. This might become clinically relevant under pathological conditions, e.g. in vascular disorders.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1475-097X.2010.00937.xDOI Listing

Publication Analysis

Top Keywords

tissue oxygenation
8
serum levels
8
vascular endothelial
8
endothelial growth
8
levels oxygen
8
oxygen uptake
8
near-infrared spectroscopy
8
wbv
6
exercise
5
muscle tissue
4

Similar Publications

For noninvasive light-based physiological monitoring, optimal wavelengths of individual tissue components can be identified using absorption spectroscopy. However, because of the lack of sensitivity of hardware at longer wavelengths, absorption spectroscopy has typically been applied for wavelengths in the visible (VIS) and near-infrared (NIR) range from 400 to 1,000 nm. Hardware advancements in the short-wave infrared (SWIR) range have enabled investigators to explore wavelengths in the ~1,000 nm to 3,000 nm range in which fall characteristic absorption peaks for lipid, protein, and water.

View Article and Find Full Text PDF

Adipokines regulate the development and progression of MASLD through organellar oxidative stress.

Hepatol Commun

February 2025

Central laboratory, Endocrine and Metabolic Diseases Hospital of Shandong First Medical University, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, Shandong, China.

The prevalence of metabolic dysfunction-associated steatotic liver disease (MASLD), which is increasingly being recognized as a leading cause of chronic liver pathology globally, is increasing. The pathophysiological underpinnings of its progression, which is currently under active investigation, involve oxidative stress. Human adipose tissue, an integral endocrine organ, secretes an array of adipokines that are modulated by dietary patterns and lifestyle choices.

View Article and Find Full Text PDF

Unlabelled: Engineered three-dimensional (3D) tissue culture platforms are useful for reproducing and elucidating complex in vivo biological phenomena. Spheroids, 3D aggregates of living cells, are produced based on physicochemical or microfabrication technologies and are commonly used even in cancer pathology research. However, conventional methods have difficulties in constructing 3D structures depending on the cell types, and require specialized techniques/lab know-how to reproducibly control the spheroid size and shape.

View Article and Find Full Text PDF

Effect of anemoside B4 on ameliorating cerebral ischemic/reperfusion injury.

Iran J Basic Med Sci

January 2025

Department of Basic Medicine, Chongqing Three Gorges Medical College, Chongqing 404100, China.

Objectives: Anemoside B4 (AB4) is a multifunctional compound with anti-inflammatory, anti-apoptotic, antioxidant, antiviral, and autophagy-enhancing effects. However, the role of AB4 in cerebral ischemia/reperfusion injury (CIRI) remains obscure. This experiment aims to investigate the pharmacological effects of AB4 in CIRI.

View Article and Find Full Text PDF

This study aimed to evaluate the impact of different manipulation methods and storage environments on the microstructural, chemical, and mechanical properties of calcium-enriched mixture (CEM) cement. Four sample groups were examined, including nondried (ND-I) and dried (D-I) groups placed directly in an incubator, dried samples stored in phosphate-buffered saline (PBS) (D-P), and dried samples stored in distilled water (D-W). Various analyses, including Vickers microhardness, compressive strength, Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) were conducted after incubating the samples for 7 days.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!