Study Design: The current study involves a cadaveric specimen with navigated pedicle screw placement using conventional reference markers and isocentric 3D fluoroscopy and also minimally invasive reference marker use with a flat panel 3D scanner.
Objective: To test the feasibility of a novel minimally invasive reference marker system for navigated pedicle screw placement in combination the use of a new imaging modality i.e. flat panel 3D imaging.
Summary Of Background Data: A major limiting factor of navigated pedicle screw placement is the requirement for intraosseous fixation of reference markers. This usually necessitates an open approach to the spinous process. To address this issue, the current authors have developed a minimally-invasive fixation device for spinal reference marker fixation.
Methods: A fresh-frozen cadaver with no history of spinal injury or deformity was positioned prone on a radiolucent table. L3 and L4 vertebrae were randomly selected for conventional pedicle screw insertion while T5 and T6 were selected for the percutaneous technique. A flat detector 3D C-arm (Ziehm vision FD 3D; Ziehm, Nuremberg, Germany) was used to evaluate the position of the pedicle screws at the vertebral levels targeted in the study.
Results: All screws placed within the lumbar spine involved conventional reference markers. The average depth deviation was 0.73 mm and the average axis deviation was 1.67 mm. Within the thoracic spine, the minimally-invasive marker fixation devices were used. The average depth deviation was 0.85 mm and the average axis deviation was 1.75 mm. In both cases, the plan and navigation were performed satisfactorily. The Y-jaw clamp for minimally-invasive reference fixation seemed to provide stable and robust fixation of the markers, requiring only two small incisions.
Conclusions: The minimally invasive reference marker system produced results which were comparable to the conventional intra-osseous markers while the flat detector-based navigation was shown to be easier to use and faster than isocentric Iso-3D technology.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3233/THC-2010-0572 | DOI Listing |
Eur Spine J
January 2025
Center for Musculoskeletal Surgery, Charité- Universitätsmedizin Berlin, Charitéplatz 1, 10117, Berlin, Germany.
Purpose: Although idiopathic scoliosis is a common three-dimensional deformity, there is a lack of studies evaluating the associations between the aortic-vertebral distance (AVD) and spinal deformities in all planes. The study therefore aimed to evaluate how the coronal and sagittal curvature, vertebral rotation and aortic-vertebral angle (AVA) affect the AVD in idiopathic scoliosis.
Methods: The AVD, AVA, vertebral rotation and curve angles were measured on preoperative magnetic resonance imaging and radiographs in 46 patients who underwent posterior spinal fusion with pedicle screw instrumentation for idiopathic scoliosis Lenke types 1 and 2.
J Orthop
July 2025
Orthopedic Spine Surgeon, USA.
Background: High-grade Isthmic Spondylolisthesis often requires surgical intervention for spinal realignment and decompression. This study describes a modified Bohlman procedure utilizing robotic-assisted navigation and a Globus SI-LOK interbody device.
Methods: A retrospective review was conducted on three patients who underwent the modified Bohlman procedure for high-grade spondylolisthesis at a single hospital between 2022 and 2023.
Global Spine J
January 2025
Department of Orthopedics, IRCCS Galeazzi Orthopaedic Institute, Milan, Italy.
Study Design: Narrative Review.
Objective: The management of spinal tumors requires a multi-disciplinary approach including surgery, radiation, and systemic therapy. Surgical approaches typically require posterior segmental instrumentation to maintain long-term spinal stability.
Musculoskelet Surg
January 2025
Department of Trauma and Orthopaedic Surgery, Barts Health NHS Trust, Royal London Hospital, London, E11BB, England.
3D-printed (3DP) drill guides have demonstrated significant potential to accurately guide pedicle screw insertion in spinal surgery. However, their role in the upper cervical spine is not well established. This review aimed to compare the efficacy and safety of 3DP drill guides to the conventional fluoroscopic-guided free-hand technique for pedicle screw insertion in the upper cervical spine.
View Article and Find Full Text PDFSpine Deform
January 2025
Pediatrics and Neurosurgery, Cedars Sinai Medical Center, Los Angeles, CA, USA.
Introduction: Congenital lumbar kyphosis is present in about 15% of patients with myelomeningocele. Worsening of deformity with complications such as chronic skin ulcers and bone exposure is common. In patients under 8 years of age, treatment becomes even more challenging: in addition to resecting the apex of the kyphotic deformity, we should ideally stabilize the spine with fixation methods that do not interrupt the growth of the rib cage, associated with the challenging pelvic fixation in this population.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!