A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Increasing medical staff safety by using a closed system for intravesical instillation of mitomycin C. | LitMetric

Objectives: Intravesical treatment with mitomycin C (MMC) after trans-urethral resection of bladder tumor is indicated by the guidelines of the European Association of Urology and the American Urology Association. MMC solution is highly irritative to skin and mucous membranes and may be of potential harm to staff handling it. We describe a closed-system device that we have developed for MMC intravesical instillation immediately after transurethral resection of bladder tumor (TURBT) for bladder cancer.

Material And Methods: A design was developed based on three requirements of a closed system for intravesical instillation of cytotoxic drug: (1) the connection of the system with the MMC administration device (e.g., syringe) must prevent any spillage or spraying of the drug solution. (2) the system should automatically close in the absence of a syringe at the connecting hub.(3) the system should have a draining mode to enable rapid drug and urine drainage into a commercially available urine bag using conventional attachments.

Results: In the system developed, MMC syringe is screwed to the connector. The valve is directed to the urinary bladder, and the MMC is injected. At the end of the therapy, the valve is directed to the collecting bag and the MMC and connector are disposed according to the guidelines for hazardous material disposal.

Conclusions: To our knowledge, this is the first report of a closed system specifically designed to reduce staff exposure during instillation of MMC. No single case of MMC spill or occupational exposure has been reported since the closed system was introduced.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.urology.2010.02.058DOI Listing

Publication Analysis

Top Keywords

closed system
16
intravesical instillation
12
mmc
9
system
8
system intravesical
8
resection bladder
8
bladder tumor
8
developed mmc
8
valve directed
8
increasing medical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!