Background: Previous Food and Drug Administration (FDA)-approved enzyme-linked immunosorbent assay testing of Dermatophagoides pteronyssinus diagnostic extracts showed potencies of 36% to 44% for 3 European extracts relative to the FDA standard (10,000 AU/mL).

Objective: To compare biological activity of various European D pteronyssinus diagnostic extracts against an FDA-validated extract using quantitative skin prick tests.

Methods: Six diagnostic D pteronyssinus extracts (1 reference extract, which was made up of 10,000 AU/mL of the FDA-approved extract; 3 European extracts; 1 US-Mexican extract, which is imported as raw material from the United States and sold in Mexico; and 1 Mexican extract) were tested during 2 skin prick test sessions as a concentrate and 2 serial 2-fold dilutions, in quadruplicate, on the backs of 19 patients with D pteronyssinus allergic rhinitis. The Wilcoxon test for linked random samples was used in each group to investigate whether the distribution of the reference extract differed from each of the test extracts to a statistically significant degree (test level alpha = .05).

Results: Extracts showed good dose response in wheal size for the concentrate compared with the 2 dilutions (steep part of the curve). All 3 European extracts (2-sided asymptotic significance, P = .003, P = .009, and P = .01, respectively) and 1 Mexican (P < .001) extract were less potent than the reference extract. European extracts varied in potency from 5,400 to 6,126 AU/mL, the US-Mexican extract had a potency of 7,444 AU/mL, and the Mexican extract had a potency of 2,099 AU/mL.

Conclusions: Our study confirmed the results from previous in vitro testing. Various diagnostic extracts of D pteronyssinus used in Europe and Mexico are less potent than those used in the United States. Similar comparisons using therapeutic extracts would be of interest.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.anai.2010.03.009DOI Listing

Publication Analysis

Top Keywords

diagnostic extracts
16
european extracts
16
skin prick
12
pteronyssinus diagnostic
12
extracts
12
united states
12
reference extract
12
extract
10
prick test
8
dermatophagoides pteronyssinus
8

Similar Publications

The intelligent identification of wear particles in ferrography is a critical bottleneck that hampers the development and widespread adoption of ferrography technology. To address challenges such as false detection, missed detection of small wear particles, difficulty in distinguishing overlapping and similar abrasions, and handling complex image backgrounds, this paper proposes an algorithm called TCBGY-Net for detecting wear particles in ferrography images. The proposed TCBGY-Net uses YOLOv5s as the backbone network, which is enhanced with several advanced modules to improve detection performance.

View Article and Find Full Text PDF

The safety and reliability of rotating machinery hinge significantly on the proper functioning of rolling bearings. In the last few years, there have been significant advances in the algorithms for intelligent fault diagnosis of bearings. However, the vibration signals collected by machines are inevitably affected by irrelevant noise because of the complex working environments of bearings.

View Article and Find Full Text PDF

Ensuring everyone enjoys healthy lifestyles and well-being at all ages, Progress has been made in increasing access to clean water and sanitation facilities and reducing the spread of epidemics and diseases. The synthesis of nano-particles (NPs) by using microalgae is a new nanobiotechnology due to the use of the biomolecular (corona) of microalgae as a capping and reducing agent for NP creation. This investigation explores the capacity of a distinct indigenous microalgal strain to synthesize silver nano-particles (AgNPs), as well as its effectiveness against multi-drug resistant (MDR) bacteria and its ability to degrade Azo dye (Methyl Red) in wastewater.

View Article and Find Full Text PDF

Prognostic role of aetiological agent vs. clinical pattern in candidates to lead extraction for cardiac implantable electronic device infections.

Sci Rep

December 2024

Department of Medical and Surgical Sciences, Institute of Cardiology, University of Bologna, Policlinico S.Orsola-Malpighi, via Massarenti 9, Bologna, 40138, Italy.

Cardiac implantable electronic devices infections (CIEDI) are associated with poor survival despite the improvement in transvenous lead extraction (TLE). Aetiology and systemic involvement are driving factors of clinical outcomes. The aim of this study was to explore their contribute on overall mortality.

View Article and Find Full Text PDF

Biological systems are complex, encompassing intertwined spatial, molecular and functional features. However, methodological constraints limit the completeness of information that can be extracted. Here, we report the development of INSIHGT, a non-destructive, accessible three-dimensional (3D) spatial biology method utilizing superchaotropes and host-guest chemistry to achieve homogeneous, deep penetration of macromolecular probes up to centimeter scales, providing reliable semi-quantitative signals throughout the tissue volume.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!