The filleted ellipse technique is useful for taking initial Mohs layers on linear excisions with positive margins.

Dermatol Surg

Division of Mohs Micrographic Surgery, Department of Dermatology, Henry Ford Health System, Detroit, Michigan, USA.

Published: June 2010

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1524-4725.2010.01571.xDOI Listing

Publication Analysis

Top Keywords

filleted ellipse
4
ellipse technique
4
technique initial
4
initial mohs
4
mohs layers
4
layers linear
4
linear excisions
4
excisions positive
4
positive margins
4
filleted
1

Similar Publications

Freshness in Salmon by Hand-Held Devices: Methods in Feature Selection and Data Fusion for Spectroscopy.

ACS Food Sci Technol

December 2024

National Measurement Laboratory: Centre of Excellence in Agriculture and Food Integrity, Institute for Global Food Security, School of Biological Sciences, Queen's University Belfast, Belfast BT9 5DL, U.K.

Salmon fillet was analyzed via hand-held optical devices: fluorescence (@340 nm) and absorption spectroscopy across the visible and near-infrared (NIR) range (400-1900 nm). Spectroscopic measurements were benchmarked with nucleotide assays and potentiometry in an exploratory set of experiments over 11 days, with changes to spectral profiles noted. A second enlarged spectroscopic data set, over a 17 day period, was then acquired, and fillet freshness was classified ±1 day via four machine learning (ML) algorithms: linear discriminant analysis, Gaussian naïve, weighted -nearest neighbors, and an ensemble bagged tree method.

View Article and Find Full Text PDF

Geometric analysis of ruptured and nonruptured abdominal aortic aneurysms.

J Vasc Surg

January 2019

Interfaculty Initiative in Information Studies/Institute of Industrial Science, University of Tokyo, Tokyo, Japan.

Objective: The objective of this study was to use parameters to determine the geometric differences between ruptured abdominal aortic aneurysms (AAAs) and nonruptured AAAs.

Methods: Computed tomography data of 38 ruptured AAAs and 215 electively repaired (nonruptured) AAAs were collected from multiple institutes. We compared the ruptured AAA group and nonruptured AAA group with 1:1 matching by using the Mahalanobis distance, which was calculated using the patient's age, sex, and AAA diameter.

View Article and Find Full Text PDF

Biomechanical analysis of an aortic aneurysm model and its clinical application to thoracic aortic aneurysms for defining "saccular" aneurysms.

J Am Heart Assoc

January 2015

Division of Vascular Surgery, Department of Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan (T.A., K.H., Y.N., K.S., T.W.).

Background: We aimed to develop a simple structural model of aortic aneurysms using computer-assisted drafting (CAD) in order to create a basis of definition for saccular aortic aneurysms.

Methods And Results: We constructed a simple aortic aneurysm model with 2 components: a tube similar to an aorta and an ellipse analogous to a bulging aneurysm. Three parameters, including the vertical and horizontal diameters of the ellipse and the fillet radius, were altered in the model.

View Article and Find Full Text PDF

The filleted ellipse technique is useful for taking initial Mohs layers on linear excisions with positive margins.

Dermatol Surg

June 2010

Division of Mohs Micrographic Surgery, Department of Dermatology, Henry Ford Health System, Detroit, Michigan, USA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!