An electrically tunable bandpass filter is designed and fabricated by integrating two solid-core photonic crystal fibers filled with different liquid crystals in a double silicon v-groove assembly. By separately controlling the driving voltage of each liquid-crystal-filled section, both the short-wavelength edge and the long-wavelength edge of the bandpass filter are tuned individually or simultaneously with the response time in the millisecond range.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.35.001608DOI Listing

Publication Analysis

Top Keywords

bandpass filter
12
electrically tunable
8
tunable bandpass
8
solid-core photonic
8
photonic crystal
8
crystal fibers
8
fibers filled
8
liquid crystals
8
filter solid-core
4
filled multiple
4

Similar Publications

Patients With .

J Neurotrauma

December 2024

Department of Medical Sciences, Section of Neurosurgery, Uppsala University, Uppsala, Sweden.

This study compared the roles of extraparenchymal autonomic nervous system (ANS) control of cerebral blood flow (CBF) versus intraparenchymal cerebrovascular autoregulation in 487 patients with aneurysmal subarachnoid hemorrhage (SAH) and 413 patients with traumatic brain injury (TBI). Vasomotion intensity of extraparenchymal and intraparenchymal vessels were quantified as the amplitude of oscillations of arterial blood pressure (ABP) and intracranial pressure (ICP) in the very low frequency range of 0.02-0.

View Article and Find Full Text PDF

This study investigates human semicircular canal (SCC) dynamics under off-center rotational conditions. Previous research has modeled human rotational perception and the dynamic response of the SCCs by assuming a centered rotation state, where the rotation axis aligns with the SCC's center. However, this assumption is not representative of most real-life rotational situations.

View Article and Find Full Text PDF

Value of P-wave Parameters in Predicting Outcomes of Repeat Catheter Ablation for Paroxysmal Atrial Fibrillation.

Pacing Clin Electrophysiol

December 2024

Department of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK.

Background: Pulmonary vein isolation (PVI) has been established as an effective management option for symptomatic paroxysmal atrial fibrillation (PAF). We aimed to explore the role of P-wave parameters in a 12-lead electrocardiogram (ECG) in predicting the success of repeat PAF ablation.

Methods: We enrolled consecutive patients who underwent a second AF ablation procedure for PAF in a UK tertiary center after an index ablation conducted between 2018 and 2019 and a repeat ablation up to 2021.

View Article and Find Full Text PDF

Background: Measurement noise often leads to inaccurate shear wave phase velocity estimation in ultrasound shear wave elastography. Filtering techniques are commonly used for denoising the shear wavefields. However, these filters are often not sufficient, especially in fatty tissues where the signal-to-noise ratio (SNR) can be very low.

View Article and Find Full Text PDF

Objective: Alzheimer's disease (AD) and frontotemporal dementia (FTD) are prevalent neurodegenerative diseases characterized by altered brain functional connectivity (FC), affecting over 100 million people worldwide. This study aims to identify distinct FC patterns as potential biomarkers for differential diagnosis.

Methods: Resting-state EEG data from 36 AD patients, 23 FTD patients, and 29 healthy controls were analyzed using time-frequency and bandpass filtering FC metrics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!