Oxygen measurements via phosphorescence.

Comput Methods Programs Biomed

Department of Medical Education, United Arab Emirates University, Faculty of Medicine and Health Sciences, Al Ain, United Arab Emirates.

Published: December 2010

Accurate measurements of dissolved O(2) as a function of time have numerous chemical and biological applications. The Pd (II) complex of meso-tetra-(4-sulfonatophenyl)-tetrabenzoporphyrin (Pd phosphor) was used for this purpose. Detection is based on the principle that the phosphorescence of this oxygen probe is inversely related to dissolved O(2) (O(2) quenches the phosphorescence). Biologic samples containing the Pd phosphor were flashed (10/s) with a peak output of 625nm; emitted light was detected at 800nm. Amplified pulses of phosphorescence were digitized at 1-2MHz using an analog/digital converter (PCI-DAS 4020/12 I/O Board) with outputs ranging from 1 to 20MHz. Assessment revealed a customized program was necessary. Pulses were captured using a developed software at 0.1-4MHz, depending on the speed of the computer. O(2) concentration was calculated by fitting to an exponential the decay of the phosphorescence. Twelve tasks were identified, which allowed full control and customization of the data acquisition, storage and analysis. The program used Microsoft Visual Basic 6 (VB6), Microsoft Access Database 2007, and a Universal Library component that allowed direct reading from the PCI-DAS 4020/12 I/O Board. It involved a relational database design to store experiments, pulses and pulse metadata, including phosphorescence decay rates. The method permitted reliable measurements of cellular O(2) consumption over several hours.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cmpb.2010.04.009DOI Listing

Publication Analysis

Top Keywords

pci-das 4020/12
8
4020/12 i/o
8
i/o board
8
phosphorescence
6
oxygen measurements
4
measurements phosphorescence
4
phosphorescence accurate
4
accurate measurements
4
measurements dissolved
4
dissolved function
4

Similar Publications

Oxygen measurements via phosphorescence.

Comput Methods Programs Biomed

December 2010

Department of Medical Education, United Arab Emirates University, Faculty of Medicine and Health Sciences, Al Ain, United Arab Emirates.

Accurate measurements of dissolved O(2) as a function of time have numerous chemical and biological applications. The Pd (II) complex of meso-tetra-(4-sulfonatophenyl)-tetrabenzoporphyrin (Pd phosphor) was used for this purpose. Detection is based on the principle that the phosphorescence of this oxygen probe is inversely related to dissolved O(2) (O(2) quenches the phosphorescence).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!