Dynamic MR angiography (MRA) of spinal vascular diseases at 3T.

Eur Radiol

Department of Neuroradiology, DISIM, Geneva University Hospital, 4 Gabrielle-Perret-Gentil, 1211, Genève 14, Switzerland.

Published: October 2010

Spinal magnetic resonance angiography (MRA) is difficult to perform because of the size of the spinal cord vessels. High-field MR improves resolution and imaging speed. We examined 17 patients with spinal vascular diseases with dynamic contrast-enhanced three-dimensional MR sequences. In three patients, the artery of Adamkievicz could be seen; we could also detect all arteriovenous malformations and dural fistulas. MRA has the potential to replace diagnostic spinal angiography and the latter should be used only for therapeutic purposes.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-010-1815-6DOI Listing

Publication Analysis

Top Keywords

angiography mra
8
spinal vascular
8
vascular diseases
8
spinal
5
dynamic angiography
4
mra spinal
4
diseases spinal
4
spinal magnetic
4
magnetic resonance
4
resonance angiography
4

Similar Publications

Sex-specific anatomical variation of circle of Willis arteries.

Neuroimage

January 2025

Department of Neurology and Neurosurgery, University Medical Center Utrecht Brain Center, University Medical Center Utrecht, Utrecht University, the Netherlands. Electronic address:

Background: Anatomical variations in the circle of Willis (CoW) arteries are common and can affect hemodynamic stress, thereby influencing the risk of cerebrovascular pathology. Previous studies have suggested sex differences in CoW anatomy, but findings vary due to limited study population size and different measurement methods. This study aims to investigate sex differences in artery diameters, anatomical variants and bifurcation angles of the CoW using a large population cohort and semi-automatic measurements.

View Article and Find Full Text PDF

To validate the clinical feasibility of deep learning-driven magnetic resonance angiography (DL-driven MRA) collateral map in acute ischemic stroke. We employed a 3D multitask regression and ordinal regression deep neural network, called as 3D-MROD-Net, to generate DL-driven MRA collateral maps. Two raters graded the collateral perfusion scores of both conventional and DL-driven MRA collateral maps and measured the grading time.

View Article and Find Full Text PDF

Among acute mastoiditis (AM) complications, cerebral venous sinus thrombosis (CVST) is particularly severe, leading to increased intracranial pressure and potential neurological sequelae. Predicting the development of such complications is challenging. The aims of the present study were to evaluate the incidence, clinical characteristics, and risk factors for the development of CVST in AM.

View Article and Find Full Text PDF

Purpose: To compare the diagnostic accuracy of CT angiography (CTA), MR angiography (MRA), and their combined use for detecting unruptured intracranial aneurysms (UIAs).

Methods: Between September 2019 and August 2023, 235 patients suspected of having UIA underwent CTA, MRA, and digital subtraction angiography (DSA)/3-dimensional rotational angiography (3DRA). Two neuroradiologists retrospectively reviewed these images for UIA presence.

View Article and Find Full Text PDF

PEGylated Ultrasmall Iron Oxide Nanoparticles as MRI Contrast Agents for Vascular Imaging and Real-Time Monitoring.

ACS Nano

January 2025

Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.

Accurate imaging evaluations of pre- and post-treatment of cardiovascular diseases are pivotal for effective clinical interventions and improved patient outcomes. However, current imaging methods lack real-time monitoring capabilities with a high contrast and resolution during treatments. This study introduces PEGylated ultrasmall iron oxide nanoparticles (PUSIONPs), which have undergone comprehensive safety evaluations, boasting an value of 6.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!