A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Highly sensitive determination of cadmium and lead in leached solutions from ceramic ware by graphite furnace atomic absorption spectrometry coupled with sequential injection-based solid phase extraction method. | LitMetric

A fully automated pretreatment system based on sequential injection solid-phase extraction (SPE) coupled to a graphite furnace atomic absorption spectrometer (Auto-Pret-GFAAS system) was developed to determine trace amounts of cadmium and lead. A handmade minicolumn packed with a chelating resin was used for the preconcentration of both metals. All protocol for the on-line SPE method was controlled by home-made software. A trigger switch that was placed next to the graphite furnace was used to synchronize the home-made software with built-in software in the GFAAS. One milliliter of sample solution was flowed through into the minicolumn, the analytes were collected and concentrated on the solid phase, and the analytes were eluted with nitric acid (3 M), and detected by GFAAS. The limits of detection (3sigma) for cadmium and lead were 0.20 and 2.6 ng L(-1), respectively. The sample throughput was 47 h(-1) for 1 mL sample loading. The proposed sensitive method with the original Auto-Pret-GFAAS system was applied to the determination of cadmium and lead in tap water and in leached solutions from ceramic ware using 4% acetic acid.

Download full-text PDF

Source
http://dx.doi.org/10.2116/analsci.26.597DOI Listing

Publication Analysis

Top Keywords

cadmium lead
16
graphite furnace
12
determination cadmium
8
leached solutions
8
solutions ceramic
8
ceramic ware
8
furnace atomic
8
atomic absorption
8
solid phase
8
auto-pret-gfaas system
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!