We reported a case of a 72-year-old male, known diabetic on insulin, referred because of complete atrioventricular block. He was found to have acute hepatitis during which he developed transient atrial arrhythmia, and sinus node dysfunction. His cardiac symptoms disappeared completely after hepatitis improvement. All of his cardiac investigations were normal including electrocardiogram, echocardiography and thalium stress test. At 3 and 6 months follow up, his Holter monitoring did not show any further arrhythmia, and he denied any further episodes of palpitation or pre-syncope. We reviewed the literature regarding the relationship between hepatitis and atrial arrhythmia.

Download full-text PDF

Source

Publication Analysis

Top Keywords

sinus node
8
node dysfunction
8
acute hepatitis
8
atrial arrhythmia
8
transient sinus
4
dysfunction acute
4
hepatitis
4
hepatitis unknown
4
unknown etiology
4
etiology reported
4

Similar Publications

Minimizing for Maximum Benefit: An Illustrative Case-Series of Atrial Only Leadless Pacing.

Pacing Clin Electrophysiol

December 2024

Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York Presbyterian Hospital, New York, USA.

Leadless pacing technology now includesdedicated atrial helix-fixation leadless pacemakers (LPs), expanding theapplication of leadless devices for patients with sinus node dysfunction andatrioventricular block during sinus rhythm. This first reportedcase-series of atrial LPs describes and discusses the potential use-casescenarios of recently approved helix-fixation atrial LPs. The article highlights important concepts regarding their use, including implantationtechniques, programming, battery conservation, and the low rate of progressionof AV block in patients implanted with AAI(R) pacemakers.

View Article and Find Full Text PDF

Reel's syndrome (RS) is an unusual cause of pacemaker lead dislodgement. We present the case of a 59-year-old female patient with Down syndrome (DS) implanted with a dual-chamber endovascular pacemaker due to symptomatic sinus node disfunction, reporting several syncopal episodes in last days and showing abnormal electrical parameters at the 2-months follow-up due to RS. The malfunctioning device was removed and an endocardial leadless pacing system was implanted.

View Article and Find Full Text PDF

Transcriptional profile of the rat cardiovascular system at single-cell resolution.

Cell Rep

December 2024

Precision Cardiology Laboratory, The Broad Institute, Cambridge, MA 02142, USA; Cardiovascular Research Center, Massachusetts General Hospital, Boston, MA 02114, USA; Cardiology Division, Massachusetts General Hospital, Boston, MA 02114, USA. Electronic address:

We sought to characterize cellular composition across the cardiovascular system of the healthy Wistar rat, an important model in preclinical cardiovascular research. We performed single-nucleus RNA sequencing (snRNA-seq) in 78 samples in 10 distinct regions, including the four chambers of the heart, ventricular septum, sinoatrial node, atrioventricular node, aorta, pulmonary artery, and pulmonary veins, which produced 505,835 nuclei. We identified 26 distinct cell types and additional subtypes, with different cellular composition across cardiac regions and tissue-specific transcription for each cell type.

View Article and Find Full Text PDF

Background: Implantable loop recorders (ILRs) have been shown to significantly improve the detection of atrial fibrillation (AF) in patients with embolic stroke of undetermined source (ESUS). The incidence and characterization of bradyarrhythmias in this subset of patients is still unknown.

Methods: All consecutive patients who received ILRs, after an ESUS, between March 2015 and December 2022 in our Center were retrospectively enrolled and analyzed.

View Article and Find Full Text PDF

Cardiac Implantable Electronic Devices in Cardiac Transplant Patients: A Comprehensive Review.

Cardiol Rev

November 2024

Department of Cardiovascular Medicine, Cardiovascular Analytics Group, Islamabad, Pakistan.

A fraction of patients (approximately 10%) undergoing heart transplantation require permanent pacemaker (PPM) implantation due to sinus node dysfunction or atrioventricular block, occurring either shortly after surgery or later. The incidence of PPM implantation has declined to less than 5% with the introduction of bicaval anastomosis transplantation surgery. Pacing dependency during follow-up varies among recipients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!