A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of international inter-laboratory comparison tests for the diagnosis of classical swine fever from 1998 until 2007. | LitMetric

Assessment of international inter-laboratory comparison tests for the diagnosis of classical swine fever from 1998 until 2007.

Rev Sci Tech

World Organisation for Animal Health and European Union Reference Laboratory for Classical Swine Fever, Institute of Virology, Bünteweg 17, 30559 Hanover, Germany.

Published: December 2009

The inter-laboratory comparison tests for classical swine fever (CSF) laboratory diagnosis organised by the European Community Reference Laboratory for CSF are regularly performed within European Union Member States. The objective of this study was to evaluate the results of the inter-laboratory comparison tests carried out over the last decade, from 1998 until 2007, by using a statistical approach. A set of five or six lyophilised sera was sent to participants. These included sera containing CSF antibodies, sera containing antibodies against ruminant pestiviruses, sera containing CSF virus and negative sera. This study focused on the results of the diagnostic reference methods for CSF: the neutralisation test for the detection of CSF antibodies (including its interpretation) and virus isolation for the detection of CSF virus. For the detection of CSF antibodies, results were closest to what was expected by the Community Reference Laboratory when only neutralisation tests were performed. The percentage of correct results decreased as soon as the results of CSF antibody enzyme-linked immunosorbent assay were included or when sera with antibodies to ruminant pestiviruses were added to the panel. The results for the detection of CSF antibodies are still valid today, as no additional method has been introduced recently. Regarding CSF virus detection, CSF virus isolation is well established but on the way to being superseded as the reference test by reverse-transcription polymerase chain reaction.

Download full-text PDF

Source
http://dx.doi.org/10.20506/rst.28.3.1956DOI Listing

Publication Analysis

Top Keywords

detection csf
20
csf antibodies
16
csf virus
16
inter-laboratory comparison
12
comparison tests
12
csf
12
classical swine
8
swine fever
8
1998 2007
8
community reference
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!