A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the TEST 1 erythrocyte sedimentation rate system and intra- and inter-laboratory quality control using new latex control materials. | LitMetric

Background: The erythrocyte sedimentation rate (ESR) test has been considered to be a simple procedure, not requiring quality control (QC). However, QC is essential for accuracy and precision. We evaluated the TEST 1 ESR system and performed QC procedures using newly developed latex control materials in three hospitals.

Methods: Using tripotassium ethylenediaminetetraacetic acid blood samples (n=184), we compared TEST 1 ESR values with Westergren ESR data and evaluated intra-assay precision. Three levels of latex control materials were used to assess inter-assay precision. Reference range assessment was done using samples from 220 healthy individuals. Inter-laboratory QC with latex control materials in three hospitals was performed.

Results: Correlation between TEST 1 ESR and Westergren ESR results was good (p<0.001). Intra-assay precision [coefficients of variation (CV) 6.6%-21.7%] with patient samples and inter-assay precision (CV 0.0%-6.8%) with latex control materials were satisfactory. The reference ranges of 2-10 mm/h for males and 2-19 mm/h for females were established. Inter-laboratory QC data with latex control materials in three hospitals demonstrated good accuracy and satisfactory precision (CV 0.0%-14.4%).

Conclusions: Our results demonstrate that the TEST 1 QC is reliable and the latex control materials are valuable for inter-laboratory proficiency testing.

Download full-text PDF

Source
http://dx.doi.org/10.1515/CCLM.2010.162DOI Listing

Publication Analysis

Top Keywords

latex control
16
control materials
16
test esr
12
erythrocyte sedimentation
8
sedimentation rate
8
quality control
8
materials three
8
westergren esr
8
control
6
esr
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!