  • The study aims to examine the relationships between four perimetric tests for glaucoma patients and compare their effective dynamic ranges.
  • Researchers analyzed data from 152 glaucoma patients and 80 controls using various perimetry methods to determine associations and dynamic range thresholds.
  • Findings indicate that while larger stimuli (size V) offer a broader effective dynamic range and more discriminable steps than smaller stimuli (size III), both show linear associations up to certain sensitivity levels.

Article Abstract

Objectives: To establish the associations between threshold estimates of 4 perimetric tests and to define and compare the tests' effective dynamic ranges.

Methods: We examined 152 patients with glaucoma and 80 controls using standard automated perimetry (SAP) with stimulus size III, SAP with size V, and motion and matrix perimetry. We explored the intertest associations using principal-components analysis. We defined the effective dynamic range bottom using the frequency of 0-dB trials on retest. We defined the upper effective dynamic range as a value above which fewer than 0.5% of the values fall in the controls. We also calculated the number of discriminable steps from normal to the floor value of the perimeter.

Results: The association between SAP III and V was approximately linear up to a sensitivity of about 20 dB on both tests and with motion and matrix perimetry up to about 25 dB from 0 dB. While the upper bounds were similar among the tests, size V SAP had a lower floor and more discriminable steps.

Conclusions: The effective dynamic range of SAP III is substantially less than its physically tested limits. Size V stimuli have a greater effective dynamic range than size III by about 1 log unit and have about twice as many discriminable steps.

Download full-text PDF

Source
http://dx.doi.org/10.1001/archophthalmol.2010.71DOI Listing

Publication Analysis

Top Keywords

effective dynamic
24
dynamic range
16
motion matrix
12
matrix perimetry
12
standard automated
8
automated perimetry
8
size iii
8
discriminable steps
8
sap iii
8
effective
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!