Precision of navigated and conventional open-wedge high tibial osteotomy in a cadaver study.

Eur J Med Res

Department of Orthopaedic Surgery, University Hospital Carl Gustav Carus, Medical Faculty of the Technical University of Dresden, Germany.

Published: March 2010

High tibial osteotomy (HTO) is an established treatment option for isolated medial osteoarthritis in young and active patients. One important factor for success of this procedure is the degree of correction of the weight-bearing line. Computer-assisted navigation systems are believed to improve the precision of axis correction through intraoperative real-time monitoring. This study investigates the precision of correction of the weight-bearing line in open-wedge HTO with and without a navigation system. Nineteen legs of well-preserved human cadaver were randomly assigned to navigated (n = 10) or conventional (n = 9) HTO. In order to achieve a sufficient amount of correction in all legs the weight-bearing line was aimed at 80 percent of the width of the tibial plateau. The mean deviation of the weight-bearing line from the desired 80 percent was 1 percent in the navigated and 8.6 percent in the conventional operated legs (p = 0.002). The weight-bearing line of all navigated but only 5 of the 9 conventional operated legs was within a +/- 5 percent tolerance level (p = 0.33). Navigated open-wedge HTO achieved better correction of the weight-bearing line than the conventional method in human cadaver legs. Future studies have to prove this advantage in a clinical setting and it's effect on patient outcome.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3352217PMC
http://dx.doi.org/10.1186/2047-783x-15-3-117DOI Listing

Publication Analysis

Top Keywords

navigated conventional
12
correction weight-bearing
12
high tibial
8
tibial osteotomy
8
open-wedge hto
8
human cadaver
8
conventional operated
8
operated legs
8
weight-bearing
6
conventional
5

Similar Publications

Background: Pain of a chronic nature remains the foremost concern in tertiary spine clinics, yet its elusive nature and quantification challenges persist. Despite extensive research and education on low back pain (LBP), the realm of diagnostic practices lacks a unified approach. Clinically, LBP exhibits a multifaceted character, encompassing conventional assessments of severity and disability, alongside nuanced attributes like pain characterization, duration, and patient expectations.

View Article and Find Full Text PDF

The laser-induced fluorescence technique has the advantage of fast and non-destructive detection and can be used to classify types of marine microplastics. However, spectral overlap poses a challenge for qualitative and quantitative analysis by conventional fluorescence spectroscopy. In this paper, a 405 nm excitation laser source was used to irradiate 4 types of microplastic samples with different concentrations, and a total of 1600 sets of fluorescence spectral data were obtained.

View Article and Find Full Text PDF

: Surgical accuracy in total knee replacement (TKR) may vary with the surgeon, the patient preoperative deformity, and the guiding system to perform the procedure. Navigation systems attempt to increase the intraoperative information the surgeon requires to make the appropriate decisions, sometimes associating cumbersome procedures and unclear effectiveness to place the implant more precisely than conventional instruments. : We conducted a retrospective case-control study with prospective data collection of radiographic measurements (alignment, joint line and patellar height) in a sample of 100 consecutive patients receiving TKR Optetrak Logic PS, either with standard surgical technique with Trulion Instrumentation ( = 59) or with the Guided Personalized Surgery (GPS) system ( = 41).

View Article and Find Full Text PDF

Bioprinting, an innovative combination of biotechnology and additive manufacturing, has emerged as a transformative technology in healthcare, enabling the fabrication of functional tissues, organs, and patient-specific implants. The implementation of the aforementioned, however, introduces unique intellectual property (IP) challenges that extend beyond conventional biotechnology. The study explores three critical areas of concern: IP protection for bioprinting hardware and bioinks, ownership and ethical management of digital files derived from biological data, and the implications of commercializing bioprinted tissues and organs.

View Article and Find Full Text PDF

Objectives: Minimally invasive surgery (MIS) has emerged as a promising alternative to conventional open techniques in the management of adolescent idiopathic scoliosis (AIS).

Materials And Methods: This study presents a case series of six patients who underwent MIS for AIS at a spine center, employing a synergistic blend of intraoperative fluoroscopy, cone-beam computed tomography scans, and three-dimensional navigation technology. The surgical procedures were meticulously guided, with a focus on ensuring safety and precision in posterior pedicle fixation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!