Determination of optimal sampling times for a two blood sample clearance method using (51)Cr-EDTA in cats.

J Feline Med Surg

Department of Veterinary Medical Imaging and Small Animal Orthopaedics, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium.

Published: August 2010

Estimation of the glomerular filtration rate (GFR) is a useful tool in the evaluation of kidney function in feline medicine. GFR can be determined by measuring the rate of tracer disappearance from the blood, and although these measurements are generally performed by multi-sampling techniques, simplified methods are more convenient in clinical practice. The optimal times for a simplified sampling strategy with two blood samples (2BS) for GFR measurement in cats using plasma (51)chromium ethylene diamine tetra-acetic acid ((51)Cr-EDTA) clearance were investigated. After intravenous administration of (51)Cr-EDTA, seven blood samples were obtained in 46 cats (19 euthyroid and 27 hyperthyroid cats, none with previously diagnosed chronic kidney disease (CKD)). The plasma clearance was then calculated from the seven point blood kinetics (7BS) and used for comparison to define the optimal sampling strategy by correlating different pairs of time points to the reference method. Mean GFR estimation for the reference method was 3.7+/-2.5 ml/min/kg (mean+/-standard deviation (SD)). Several pairs of sampling times were highly correlated with this reference method (r(2) > or = 0.980), with the best results when the first sample was taken 30 min after tracer injection and the second sample between 198 and 222 min after injection; or with the first sample at 36 min and the second at 234 or 240 min (r(2) for both combinations=0.984). Because of the similarity of GFR values obtained with the 2BS method in comparison to the values obtained with the 7BS reference method, the simplified method may offer an alternative for GFR estimation. Although a wide range of GFR values was found in the included group of cats, the applicability should be confirmed in cats suspected of renal disease and with confirmed CKD. Furthermore, although no indications of age-related effect were found in this study, a possible influence of age should be included in future studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10911495PMC
http://dx.doi.org/10.1016/j.jfms.2010.01.011DOI Listing

Publication Analysis

Top Keywords

reference method
16
optimal sampling
8
sampling times
8
sampling strategy
8
blood samples
8
gfr estimation
8
sample min
8
gfr values
8
method
7
gfr
7

Similar Publications

Stroke is the second-leading global cause of death. The damage attributed to the immune storm triggered by ischemia-reperfusion injury (IRI) post-stroke is substantial. However, data on the transcriptomic dynamics of pyroptosis in IRI are limited.

View Article and Find Full Text PDF

Background: Recent technological advances have introduced novel methods for measuring body composition, each with unique benefits and limitations. The choice of method often depends on the trade-offs between accuracy, cost, participant burden, and the ability to measure specific body composition compartments.

Objective: To review the considerations of cost, accuracy, portability, and participant burden in reference and emerging body composition assessment methods, and to evaluate their clinical applicability.

View Article and Find Full Text PDF

Improving Understanding of Fexofenadine Pharmacokinetics to Assess Pgp Phenotypic Activity in Older Adult Patients Using Population Pharmacokinetic Modeling.

Clin Pharmacokinet

January 2025

Clinical Pharmacology and Toxicology Service, Anesthesiology, Pharmacology and Intensive Care Department, Geneva University Hospitals, 4 Rue Gabrielle Perret-Gentil, 1205, Geneva, Switzerland.

Background And Objective: Fexofenadine is commonly used as a probe substrate to assess P-glycoprotein (Pgp) activity. While its use in healthy volunteers is well documented, data in older adult and polymorbid patients are lacking. Age- and disease-related physiological changes are expected to affect the pharmacokinetics of fexofenadine.

View Article and Find Full Text PDF

Detecting Hemorrhagic Myocardial Infarction With 3.0-T CMR: Insights Into Spatial Manifestation, Time-Dependence, and Optimal Acquisitions.

JACC Cardiovasc Imaging

January 2025

Department of Radiology and Imaging Sciences and Krannert Cardiovascular Research Center, Indiana University School of Medicine, Indianapolis, Indiana, USA. Electronic address:

Background: Hemorrhagic myocardial infarction (hMI) can rapidly diminish the benefits of reperfusion therapy and direct the heart toward chronic heart failure. T2∗ cardiac magnetic resonance (CMR) is the reference standard for detecting hMI. However, the lack of clarity around the earliest time point for detection, time-dependent changes in hemorrhage volume, and the optimal methods for detection can limit the development of strategies to manage hMI.

View Article and Find Full Text PDF

Purpose: Our goal was to determine the association between the severity of electrodiagnostic (EDX) studies with the cross-sectional area (CSA) of the ulnar nerve at the cubital tunnel using diagnostic ultrasound. Based on our clinical experience, we hypothesized there would not be a positive correlation between the severity of EDX and ulnar nerve CSA.

Methods: This was a retrospective analysis of patients 18 years or older evaluated from May 1, 2020, to June 31, 2021, referred for an upper limb EDX and neuromuscular ultrasound to evaluate for an upper limb neuropathy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!