Introduction And Objectives: To investigate the prevalence, causes and outcome of catheterization laboratory false alarms (CLFAs) in a regional primary angioplasty network.

Methods: A prospective registry of 1,662 patients referred for primary angioplasty between January 2003 and August 2008 was reviewed to identify CLFAs (i.e. when no culprit coronary lesion could be found).

Results: No culprit coronary lesion could be identified in 120 patients (7.2%; 95% confidence interval [CI], 5.9-8.5%). Of these, 104 (6.3%, 95% CI, 5.1-7.4%) had a discharge diagnosis other than ST-elevation myocardial infarction, 91 (5.5%; 95% CI, 4.3-6.6%) had no significant coronary disease, and 64 (3.8%; 95% CI, 2.9-4.8%) tested negative for cardiac biomarkers. The most frequent alternative diagnoses were: previous Q-wave myocardial infarction (18 cases), nonspecific ST-segment abnormalities (11), pericarditis (10) and transient apical dyskinesia (10). The 30-day mortality rate was similar in patients with and without culprit lesions (5.8% vs. 5.8%; P=.99). The prevalence of CLFAs was slightly higher in patients not previously evaluated by a cardiologist and referred from emergency departments in hospitals without catheterization laboratories than in those referred by cardiologists from emergency departments at hospitals with such facilities (9.5% vs. 6.1%; P=.02; odds ratio=1.64; 95% CI, 1.08-2.5). The prevalence of CLFAs was not significantly higher in patients referred by physicians with out-of-hospital emergency medical services (7.2%; P=.51; odds ratio=1.37; 95% CI, 0.79-2.37).

Conclusions: The prevalence of CLFAs was 7.2%, with the criterion of no culprit coronary lesion. Our findings suggest that different patterns of referral to catheterization laboratories could account for small variations in the prevalence of CLFAs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s1885-5857(10)70113-4DOI Listing

Publication Analysis

Top Keywords

prevalence clfas
16
myocardial infarction
12
culprit coronary
12
coronary lesion
12
outcome catheterization
8
catheterization laboratory
8
laboratory false
8
false alarms
8
st-elevation myocardial
8
primary angioplasty
8

Similar Publications

2-Chlorofatty acids are biomarkers of sepsis mortality and mediators of barrier dysfunction in rats.

J Lipid Res

July 2020

Edward A. Doisy Department of Biochemistry and Molecular Biology, Saint Louis University School of Medicine, St. Louis, MO 63104; Center for Cardiovascular Research, Saint Louis University School of Medicine, St. Louis, MO 63104. Electronic address:

Sepsis is defined as the systemic, dysregulated host immune response to an infection that leads to injury to host organ systems and, often, death. Complex interactions between pathogens and their hosts elicit microcirculatory dysfunction. Neutrophil myeloperoxidase (MPO) is critical for combating pathogens, but MPO-derived hypochlorous acid (HOCl) can react with host molecular species as well.

View Article and Find Full Text PDF

Sepsis-associated acute respiratory distress syndrome (ARDS) is characterized by neutrophilic inflammation and poor survival. Since neutrophil myeloperoxidase (MPO) activity leads to increased plasma 2-chlorofatty acid (2-ClFA) levels, we hypothesized that plasma concentrations of 2-ClFAs would associate with ARDS and mortality in subjects with sepsis. In sequential consenting patients with sepsis, free 2-ClFA levels were significantly associated with ARDS, and with 30-day mortality, for each log increase in free 2-chlorostearic acid.

View Article and Find Full Text PDF

Introduction And Objectives: To investigate the prevalence, causes and outcome of catheterization laboratory false alarms (CLFAs) in a regional primary angioplasty network.

Methods: A prospective registry of 1,662 patients referred for primary angioplasty between January 2003 and August 2008 was reviewed to identify CLFAs (i.e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!