A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Noninvasive blood pressure measurement by the Nexfin monitor during reduced arterial pulsatility: a feasibility study. | LitMetric

Noninvasive blood pressure measurements are difficult when arterial pulsations are reduced, as in patients supported by continuous flow left ventricular assist devices (cf-LVAD). We evaluated the feasibility of measuring noninvasive arterial blood pressure with the Nexfin monitor during conditions of reduced arterial pulsatility. During cardiopulmonary bypass(CPB) in which a roller pump based or a centrifugal pump based heart-lung machine generated arterial blood pressure with low pulsatility, noninvasive arterial pressures (NAP)measured by the Nexfin Monitor were recorded and compared with invasively measured radial artery pressures (IAP).We also evaluated NAP in 10 patients with a cf-LVAD during a pump speed change procedure (PSCP). During CPB in 18 patients, the NAP-IAP average difference was -1.3 +/- 6.5 mmHg. The amplitude of pressure oscillations were 4.3 +/- 3.8 mmHg measured by IAP. Furthermore, in the cf-LVAD patients, increase in pump speed settings led to an increase in diastolic and mean arterial pressures (MAP) while the NAP acquired a sinusoidal shape as the aortic valve become permanently closed. In conclusion, NAP was similar to IAP under conditions of reduced arterial pulsatility. The device also measured the blood pressure waveform noninvasively in patients supported by a cf-LVAD.

Download full-text PDF

Source
http://dx.doi.org/10.1097/mat.0b013e3181d70227DOI Listing

Publication Analysis

Top Keywords

blood pressure
20
nexfin monitor
12
reduced arterial
12
arterial pulsatility
12
noninvasive blood
8
arterial
8
patients supported
8
noninvasive arterial
8
arterial blood
8
conditions reduced
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!