A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

When unfolding is better: unique success of unfolded partial least-squares regression with residual bilinearization for the processing of spectral-pH data with strong spectral overlapping. Analysis of fluoroquinolones in human urine based on flow-injection pH-modulated synchronous fluorescence data matrices. | LitMetric

When unfolding is better: unique success of unfolded partial least-squares regression with residual bilinearization for the processing of spectral-pH data with strong spectral overlapping. Analysis of fluoroquinolones in human urine based on flow-injection pH-modulated synchronous fluorescence data matrices.

Analyst

Departamento de Química Analítica, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario e Instituto de Química Rosario (IQUIR-CONICET), Suipacha 531, Rosario (2000), Argentina.

Published: August 2009

Synchronous fluorescence spectra measured in a flow-injection system with double pH gradient modulation constitute a new second-order signal which is herein studied for the quantitative determination of three fluoroquinolone antibiotics in spiked human urine samples. Because calibration is done using aqueous solutions of each of the three analytes ciprofloxacin, norfloxacin and ofloxacin, the fluorescent urine background makes it necessary to achieve the second-order advantage. Several second-order multivariate calibration algorithms were evaluated for this purpose: parallel factor analysis, unfolded and multiway partial least-squares with residual bilinearization, and multivariate curve resolution-alternating least-squares. The best analytical figures of merit, a root mean square error of 4-6 mg L(-1) (corresponding to a relative error of 4-6% for a calibration range from 0 to 200 mg L(-1) for each analyte), and a limit of detection of 4 mg L(-1) were obtained using partial least-squares (in the specific unfolded version) combined with residual bilinearization. Reasons for the improved success of this latter technique are provided on the basis of the analysis of simulated second-order data.

Download full-text PDF

Source
http://dx.doi.org/10.1039/b903649kDOI Listing

Publication Analysis

Top Keywords

partial least-squares
12
residual bilinearization
12
human urine
8
synchronous fluorescence
8
unfolding better
4
better unique
4
unique success
4
success unfolded
4
unfolded partial
4
least-squares
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!