Contour interaction plays an important role in letter recognition and has long been known to influence clinical visual acuity measurements. LogMAR charts originally employed between-letter and line spacing of one letter width/height; however, in more recent designs, half letter width spacing has become accepted without validation. COMPlog is a computerised visual acuity measurement device being developed and validated for routine and research clinical use and is available commercially. This study was performed to investigate the effect of letter separation on computerised visual acuity measurements. An iterative series of experiments was performed in which test and retest fully interpolated five letters-per-line logMAR visual acuity measurements were taken in three groups of a total 100 adult subjects. Each group had visual acuity measured using ETDRS charts 1 and 2 and on COMPlog using various combinations of letter and line spacing. The first group consisted of 31 subjects tested using 3.75 and 2.50 stroke width spacing, the second 45 subjects using 2.50 and 1.25 stroke width spacing and the last group, 24 subjects tested using 1.90 stroke width spacing. The methods of Bland and Altman were used to analyse the data. No significant bias was noted between the gold standard ETDRS measurements and those taken using COMPlog with 3.75 stroke width spacing. Significant bias of half a logMAR line was found with crowding of 1.90 and 1.25 stroke widths. A small systematic bias with a reduction of 1 ETDRS letter was found with spacing of 2.50 stroke widths which has not been demonstrated in previous validation studies. Crowding of 2.50 stroke widths is the smallest spacing which can be used in the design of COMPlog.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1475-1313.2009.00700.xDOI Listing

Publication Analysis

Top Keywords

visual acuity
24
width spacing
20
acuity measurements
16
stroke width
16
computerised visual
12
250 stroke
12
stroke widths
12
spacing
9
letter separation
8
separation computerised
8

Similar Publications

The purpose of this study was to evaluate the stability of small-incision lenticule extraction (SMILE) and laser in situ keratomileusis (LASIK) when ascending from near sea level to an altitude of 3874 m. The visual acuity (VA), intraocular pressure (IOP), spherical equivalent refraction (SER) and biometric parameters of 20 normal subjects (40 eyes, controls) and 36 subjects who underwent corneal refractive surgery (35 eyes with SMILE and 36 eyes with LASIK) were examined in Chongqing (C, 500 m above sea level) and 7-10 days after a collective travel to Shigatse (S, 3874 m above sea level). SER and corneal thickness (CT) were choosed as main indicators of the stability of corneal refractive surgery at high altitude.

View Article and Find Full Text PDF

Real-World Evidence on Digital Therapeutics in Pediatric Amblyopia: Insights into Rapid Axial Elongation Risk.

Ophthalmology

January 2025

State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, 510060, China. Electronic address:

Objective: To evaluate the impact of daily digital therapeutics (DTx) on the risk of rapid axial elongation (RAE) in children with amblyopia using real-world data.

Design: Retrospective cohort study.

Subjects: A total of 1,394 children aged 3 to 12 years with amblyopia, of which 477 received DTx.

View Article and Find Full Text PDF

Long-term exposure to PM and its constituents and visual impairment in schoolchildren: A population-based survey in Guangdong province, China.

Environ Int

January 2025

Joint International Research Laboratory of Environment and Health, Ministry of Education, Guangdong Provincial Engineering Technology Research Center of Environmental Pollution and Health Risk Assessment, Department of Occupational and Environmental Health, School of Public Health, Sun Yat-sen University, Guangzhou 510080 China. Electronic address:

Background: Exposure to fine particulate matter (PM) has been linked to visual impairment. Nevertheless, evidence associating PM constituents with visual impairment in schoolchildren is sparse.

Objectives: To explore the effects of long-term exposure to PM and its constituents on visual impairment.

View Article and Find Full Text PDF

Purpose: To study the role of intravitreal clindamycin with dexamethasone as an adjuvant to systemic co-trimoxazole and steroids in macular Toxoplasma retinochoroiditis.

Methods: Retrospective study of Toxoplasma retinochoroiditis cases from January 2014 to December 2021 treated with a combination of oral and intravitreal therapy in immunocompetent patients.

Results: 39 eyes of 39 patients were included in this study after meeting the inclusion criteria with the mean age of presentation being 25.

View Article and Find Full Text PDF

Background: Idiopathic intracranial hypertension (IIH) is increasingly prevalent, yet longitudinal outcome data are scarce. This study aimed to characterise demographic and longitudinal clinical changes in a cohort of patients with IIH.

Methods: Retrospective cohort analysis on adult patients diagnosed with IIH (Friedman criteria) enrolled in the neuro-ophthalmology database (NODE) across two tertiary centres.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!