The interaction between dental pulp derived mesenchymal stem cells (DP-MSCs) and three different tantalum nanotopographies with and without a fibronectin coating is examined: sputter-coated tantalum surfaces with low surface roughness <0.2 nm, hut-nanostructured surfaces with a height of 2.9 +/- 0.6 nm and a width of 35 +/- 8 nm, and dome structures with a height of 13 +/- 2 nm and a width of 52 +/- 14 nm. Using ellipsometry, the adsorption and the availability of fibronectin cell-binding domains on the tantalum surfaces were examined, as well as cellular attachment, proliferation, and vinculin focal adhesion spot assembly on the respective surfaces. The results showed the highest fibronectin mass uptake on the hut structures, with a slightly higher availability of cell-binding domains and the most pronounced formation of vinculin focal adhesion spots as compared to the other surfaces. The proliferation of DP-MSCs was found to be significantly higher on dome and hut surfaces coated with fibronectin compared to the uncoated flat tantalum surfaces. Consequently, the results presented in this study indicate that fibronectin-coated nanotopographies with a vertical dimension of less than 5 nm influence cell adhesion. This rather interesting behavior is argued to originate from the more available fibronectin cell-binding domains observed on the hut structures.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/nn9017872 | DOI Listing |
Biomed Mater
December 2024
State Key Laboratory of Nuclear Physics and Technology, Department of Technical Physics, School of Physics, Peking University, Beijing 100871, People's Republic of China.
Titanium (Ti), characterized by its exceptional mechanical properties, commendable corrosion resistance and biocompatibility, has emerged as the principal functional materials for implants in biomedical and clinical applications. However, the Ti-6Al-4V (TC4ELI) alloy has cytotoxicity risks, whereas the strength of the existing industrially pure titanium TA4 is marginally inadequate and will significantly limit the scenarios of medical implants. Herein, we prepared ultrafine-grained industrial-grade pure titanium TA4 and titanium alloy TC4ELI via the equal channel angular pressing method, in which the TA4-1 sample has ultrahigh strength of 1.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2024
College of Automation, Xi'an University of Posts and Telecommunications, Xi'an 710100, China.
Janus transition metal disulfide (TMD) monolayers have two distinct carbon surfaces that break the inherent ground external mirror symmetry. When compared to traditional TMD materials, Janus TMDs not only inherit the advantages of traditional TMDs but also have new characteristics that are different from those of traditional TMDs. This paper describes the development of a stable passive Q-switched ytterbium-doped fiber laser (YDFL) with operating wavelengths of 1032.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2024
College of Material Science and Engineering, Taiyuan University of Technology, Taiyuan 030024, China.
Oxygen-free copper is utilized in nuclear processing heaters; however, it exhibits poor resistance to hydrogen radiation corrosion. A tantalum-copper diffusion layer with high vacancy concentration was prepared on the copper surface. This layer demonstrates superior hydrogen trapping and diffusion resistance compared to pure tantalum, though the underlying mechanism remains unclear.
View Article and Find Full Text PDFLangmuir
December 2024
School of Electronic and Information Engineering, Hebei University of Technology, Tianjin 300130, China.
When chemical mechanical polishing (CMP) of tantalum (Ta)-based barrier layers is done through silicon via (TSV), it is necessary to control the rate selection of copper (Cu) and Ta to prevent the formation of dishing pit formation due to the rapid removal rate (RR) of copper in the via compared to tantalum outside the via. This paper selected 2-mercapto-1-methylimidazole (TAMZ) as an inhibitor, which has the dual effect of reducing the RR of Cu and increasing the RR of Ta. The experimental results show that the rate selection ratio of Cu and Ta is up to 2.
View Article and Find Full Text PDFMed Eng Phys
December 2024
Department of Orthopaedics, University of Utah, UT, United States; Department of Biomedical Engineering, University of Utah, UT, United States. Electronic address:
This study aimed to validate the use of weightbearing computed tomography against conventional computed tomography and against bead tracking for markerless tracking of key foot and ankle bones. A left cadaveric limb was implanted with tantalum beads and underwent conventional computed tomography and weightbearing computed tomography scanning, followed by biplane fluoroscopy motion capture to simulate gait. Bone models from conventional computed tomography and weightbearing computed tomography were compared for surface differences and kinematic analysis across six joints.