As decisions in cardiology increasingly rely on noninvasive methods, fast and precise image processing tools have become a crucial component of the analysis workflow. To the best of our knowledge, we propose the first automatic system for patient-specific modeling and quantification of the left heart valves, which operates on cardiac computed tomography (CT) and transesophageal echocardiogram (TEE) data. Robust algorithms, based on recent advances in discriminative learning, are used to estimate patient-specific parameters from sequences of volumes covering an entire cardiac cycle. A novel physiological model of the aortic and mitral valves is introduced, which captures complex morphologic, dynamic, and pathologic variations. This holistic representation is hierarchically defined on three abstraction levels: global location and rigid motion model, nonrigid landmark motion model, and comprehensive aortic-mitral model. First we compute the rough location and cardiac motion applying marginal space learning. The rapid and complex motion of the valves, represented by anatomical landmarks, is estimated using a novel trajectory spectrum learning algorithm. The obtained landmark model guides the fitting of the full physiological valve model, which is locally refined through learned boundary detectors. Measurements efficiently computed from the aortic-mitral representation support an effective morphological and functional clinical evaluation. Extensive experiments on a heterogeneous data set, cumulated to 1516 TEE volumes from 65 4-D TEE sequences and 690 cardiac CT volumes from 69 4-D CT sequences, demonstrated a speed of 4.8 seconds per volume and average accuracy of 1.45 mm with respect to expert defined ground-truth. Additional clinical validations prove the quantification precision to be in the range of inter-user variability. To the best of our knowledge this is the first time a patient-specific model of the aortic and mitral valves is automatically estimated from volumetric sequences.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TMI.2010.2048756DOI Listing

Publication Analysis

Top Keywords

aortic mitral
12
mitral valves
12
patient-specific modeling
8
modeling quantification
8
best knowledge
8
model aortic
8
motion model
8
volumes 4-d
8
model
7
valves
5

Similar Publications

Percutaneous valve implantation or surgical replacement with mechanical or biological valves are standard therapies for severe valvular heart diseases. Prosthetic valve thrombosis, though rare, is a serious complication, particularly with mechanical prostheses. This study aimed to investigate the predictive value of platelet volume parameters, including mean platelet volume (MPV), platelet distribution width (PDW), and platelet-large cell ratio (P-LCR), for valvular thrombosis risk in patients undergoing valve replacement therapy.

View Article and Find Full Text PDF

Background: Permanent pacemaker (PPM) placement after mitral valve (MV) repair is affected by concomitant procedures, yet existing literature reports conflicting rates. We aimed to characterize the effect of concomitant operation on risk of need for postoperative PPM in patients who underwent MV repair.

Methods: A retrospective review of a prospectively maintained institutional database (1996-2020) was conducted of consecutive patients undergoing MV repair, including concomitant procedures.

View Article and Find Full Text PDF

Background: Concurrent aortic and mitral valve repair presents specific technical challenges to surgeons. Here we evaluate the outcomes of patients undergoing combined valve-sparing aortic root reimplantation and mitral valve repair.

Methods: We performed a retrospective review of patients at our center between 2006 and 2021 who underwent concomitant valve-sparing aortic root replacement and mitral valve repair.

View Article and Find Full Text PDF

Background: Rising rates of substance use (SU) have resulted in an increasing need for left-sided valve surgery for SU-associated infective endocarditis (SU-IE). We compared outcomes, readmissions, and costs between IE patients with and without SU-IE in a national cohort.

Methods: Using the Nationwide Readmissions Database (2016-2018), we identified 10,098 patients with infective endocarditis (IE) who underwent isolated aortic or mitral valve replacement.

View Article and Find Full Text PDF

Background: The rate of permanent pacemaker implantation after tricuspid valve (TV) operation is thought to be high, with some studies quoting rates of 20% to 30%. We identified the rate of pacemaker implantation after TV operation at a high-volume regional reference center to better characterize the contemporary risk of pacemaker.

Methods: All adult patients without preexisting pacemakers undergoing TV operation from 2011 to 2022 were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!