A simple method based on disposable gelatin gel templates has been developed for the low-cost fabrication of poly(methyl methacrylate) (PMMA) microfluidic chips. Gelatin was dissolved in glycerol aqueous solution under heat to prepare a thermally reversible impression material. The molten gel was then sandwiched between a glass plate and a SU-8 template bearing negative relief of microstructure. After cooling, the negative SU-8 template could be easily separated from the solidified gelatin gel and a layer of gelatin template bearing positive relief of the microstructure was left on the glass plate. Subsequently, prepolymerized methyl methacrylate molding solution containing a UV-initiator was sandwiched between the gel template and a PMMA plate and was allowed to polymerize under UV light to fabricate PMMA channel plate at room temperature. Complete microchips could be obtained by bonding the channel plates with covers using plasticizer-assisted thermal bonding at 90 degrees C. Gelatin gel template can be mass-produced and will find application in the mass production of PMMA microchips at low cost. The prepared microfluidic microchips have been successfully employed in the capillary electrophoresis analysis of several ions in connection with contactless conductivity detection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2010.02.028DOI Listing

Publication Analysis

Top Keywords

gelatin gel
16
low-cost fabrication
8
fabrication polymethyl
8
polymethyl methacrylate
8
disposable gelatin
8
gel templates
8
glass plate
8
su-8 template
8
template bearing
8
relief microstructure
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!