A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Note: Design and tests of a 13 kA-6.5 kV thyristor switch for a pulsed inductive vacuum ultraviolet source. | LitMetric

Note: Design and tests of a 13 kA-6.5 kV thyristor switch for a pulsed inductive vacuum ultraviolet source.

Rev Sci Instrum

Plasmaphysics Group, Institute of Applied Physics, Goethe University, Frankfurt am Main 60438, Germany.

Published: April 2010

In this paper, the design, construction, and test procedure of a closing switch prototype based on thyristors is described. In particular, details are given about the design criteria and about the triggering board architecture, which is a high side biased, self supplied unit using the electrical energy derived from a local snubber network for the gate drive. The structure guarantees a hard firing gate pulse for the required high dI/dt application. Further, the results of the prototype tests are presented and discussed. The stack assembly has a holding voltage of 6.5 kV and is used for switching a series resonant circuit with a ringing frequency of 12 kHz for a pulsed inductive vacuum ultraviolet source. Maximum current amplitudes of 13 kA and pulse energies of more than 600 J were switched during the test procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.3381071DOI Listing

Publication Analysis

Top Keywords

pulsed inductive
8
inductive vacuum
8
vacuum ultraviolet
8
ultraviolet source
8
test procedure
8
note design
4
design tests
4
tests ka-65
4
ka-65 thyristor
4
thyristor switch
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!