Objectives: Document patient choices and screening performance (false positive and detection rates) when three improved Down syndrome screening protocols were introduced coincidentally.
Method: Second-trimester 'triple marker' screening was expanded by adding second-trimester dimeric inhibin-A (four-marker), with or without first-trimester pregnancy-associated plasma protein-A (five-marker). Nuchal translucency (NT) measurements were included when available from accredited sonographers (six-marker). For assigning risk, two sets of marker distribution parameters were evaluated.
Results: Over 3.5 years, 8571 women enrolled (median age 30.6 years). Uptake of the four-, five- and six-marker protocols was 18%, 46% and 36%, respectively. Of those selecting an integrated test (five or six markers), 9.7% did not provide the second trimester serum sample. False positive rates decreased with added markers (5.2%, 5.1% and 2.5%, respectively) and varied between the two parameter sets, while detection remained high. Overall, 21 of 23 cases were detected (91%, 95% CI 73-98%) at a 4.2% false positive rate (95% CI 3.3-5.1%).
Conclusions: Integrated screening protocols were chosen 4.6 times more often than four-marker screening (82% vs. 18% uptake). Overall detection was higher and false positives lower, consistent with recent guidelines. Important performance factors include gestational dating method, risk cut-off, and the parameter set used to assign risk.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/pd.2502 | DOI Listing |
Sci Rep
January 2025
Department of Medical Pathology, Ege University Faculty of Medicine, Ege University Hospital, Bornova, İzmir, Turkey.
This study aimed to evaluate the diagnostic accuracy of ultrasonography in assessing the response of clipped axillary lymph nodes to neoadjuvant chemotherapy. Between February 2022 and September 2023, 43 patients who underwent axillary lymph node marking for targeted axillary dissection were retrospectively analyzed. Ultrasonography parameters such as the number, size, shape, cortical thickness, hilum status, and treatment response of the clipped lymph node were assessed.
View Article and Find Full Text PDFAcad Radiol
January 2025
Guangxi Medical University, Nanning, Guangxi 530021, China (C.Z., D.H., B.W., S.W., Y.S., X.W.); Guangxi Key Laboratory of Enhanced Recovery After Surgery for Gastrointestinal Cancer, Nanning, Guangxi 530021, China (C.Z., D.H., B.W., S.W., Y.S., X.W.); Department of Gastrointestinal Gland Surgery, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi 530021, China (D.H., X.W.). Electronic address:
Rationale And Objectives: Accurate preoperative pathological staging of gastric cancer is crucial for optimal treatment selection and improved patient outcomes. Traditional imaging methods such as CT and endoscopy have limitations in staging accuracy.
Methods: This retrospective study included 691 gastric cancer patients treated from March 2017 to March 2024.
Med Phys
January 2025
Breast Imaging Department, Red Cross Hospital Munich, Munich, Germany.
Background: A significant proportion of false positive recalls of mammography-screened women is due to benign breast cysts and simple fibroadenomas. These lesions appear mammographically as smooth-shaped dense masses and require the recalling of women for a breast ultrasound to obtain complementary imaging information. They can be identified safely by ultrasound with no need for further assessment or treatment.
View Article and Find Full Text PDFAnal Chem
January 2025
Key Laboratory for Green Organic Synthesis and Application of Hunan Province, Key Laboratory of Environmentally Friendly Chemistry and Applications of Ministry of Education, Hunan Provincial University Key Laboratory for Environmental and Ecological Health, College of Chemistry, Xiangtan University, Xiangtan 411105, P.R. China.
The challenge of "false positive" signals significantly complicates tumor localization and surgical resection, which are pivotal for successful tumor surgeries. Therefore, the development of a method for preoperative tumor localization and intraoperative margin determination holds considerable promise for improving surgical outcomes. In this study, a zero-crosstalk ratiometric tumor-targeting near-infrared (NIR) fluorescent probe was developed for precise cancer diagnosis and intraoperative navigation via NIR fluorescence imaging.
View Article and Find Full Text PDFEpilepsia
January 2025
Department of Clinical Neurosciences, University of Calgary, Calgary, Alberta, Canada.
Objective: Somatic variants causing epilepsy are challenging to detect, as they are only present in a subset of brain cells (e.g., mosaic), resulting in low variant allele frequencies.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!