Despite advances in polymer and drug technology, the underlying stent platform remains a key determinant of clinical outcome. A clear understanding of stent design and the differences between various stent platforms are of increasing importance for the interventional cardiologist. Reduction in stent strut thickness has been associated with improved stent deliverability, improved procedural outcome, and lower rates of subsequent restenosis. Newer-generation 316L-SS stent designs have enabled reduced strut thickness while retaining radial strength and minimizing recoil, but with significant loss of radiopacity, leading to reduced visibility. Cobalt chromium alloys have enabled a reduction in stent strut thickness to around 80-90 mm while retaining modest radiopacity, but due to higher elastic properties, have been associated with greater stent recoil. Development of a novel 33% platinum chromium alloy with high radial strength and high radiopacity has enabled design of a new, thin-strut, flexible, easily visualized, and highly trackable stent platform, the use of which is further illustrated in several clinical case descriptions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12325-010-0022-9 | DOI Listing |
J Vasc Surg
January 2025
Vascular Surgery, University of Bologna, DIMEC, Bologna, Italy; Vascular Surgery Unit, IRCCS Sant'Orsola, Bologna, Italy.
Introduction/aim: The partial deployment technique (PDT) is an unconventional option of T-branch deployment to allow target arteries (TAs) cannulation/stenting from the upper arm access, in case of narrow (NPA: <25mm) or severely angulated (APA: >60°) aorta. Aim of this study was to report outcomes of the endovascular repair of complex aortic (c-AAAs) and thoracoabdominal (TAAAs) aneurysms by T-branch and PDT.
Methods: All consecutive patients underwent urgent endovascular repair of c-AAAs and TAAAs by T-branch (Cook-Medical, Bloomington, IN, US) and PDT from 2021 to 2023 were analyzed.
PLoS One
January 2025
Laboratory for Microbiome Sciences, RIKEN Center for Integrative Medical Sciences, Kanagawa, Japan.
Biliary stent occlusion is due, in part, to biofilm formation by bacteria. However, previous culture-based approaches may not have revealed all microorganisms on the surface. Twenty-seven patients underwent endoscopic retrograde biliary drainage for the removal or replacement of plastic biliary stents.
View Article and Find Full Text PDFJ Endovasc Ther
December 2024
Institute for Vascular Research, St. Franziskus Hospital, Münster, Germany.
Background: To compare the performance of a new-generation cobalt-chromium balloon-expandable bare metal stent with a stainless steel platform for the treatment of iliac occlusive disease.
Methods: Consecutive patients treated for symptomatic iliac occlusive disease between 2014 and 2021 with the cobalt-chromium Dynetic-35 or the stainless steel Dynamic platform were retrospectively evaluated. Outcome measures included technical success, device- or procedure-related death, clinically-driven target lesion revascularization (CD-TLR), primary patency, and major index limb amputation up to 12 months.
J Cardiothorac Surg
December 2024
Department of Medical Informatics, Medical School of Nantong University, Nantong, 226001, China.
Background: The classification of major adverse cardiovascular event (MACE) endpoints in patients with type 2 diabetes mellitus (T2DM) and either confirmed coronary artery disease (CAD) or high CAD risk, as well as the extent of the association between T2DM and coronary plaque characteristics, remains uncertain.
Purpose: This meta-analysis aims to compare MACE endpoints between patients with diabetes and patients without diabetes based on coronary artery plaques.
Methods: We searched studies from Web of Science, PubMed, Embase, and the Cochrane Library up until September 1, 2023.
Chin Neurosurg J
December 2024
Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100070, China.
Background: Precise diagnosis and rapid treatment for acute complex intracranial hemorrhage (ICH) are crucial. The neurosurgical hybrid operating platform integrates traditional open neurosurgery operating room functionalities with endovascular therapy capabilities and is developing in the neurosurgical practice. However, its effect on the emergent complicated neurovascular cases needs pilot exploration.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!