Images of terrestrial and marine invertebrates (snails and bivalves) have been obtained by using an X-ray phase-contrast imaging technique, namely, synchrotron-based diffraction-enhanced imaging. Synchrotron X-rays of 20, 30 and 40keV were used, which penetrate deep enough into animal soft tissues. The phase of X-ray photons shifts slightly as they traverse an object, such as animal soft tissue, and interact with its atoms. Biological features, such as shell morphology and animal physiology, have been visualized. The contrast of the images obtained at 40keV is the best. This optimum energy provided a clear view of the internal structural organization of the soft tissue with better contrast. The contrast is higher at edges of internal soft-tissue structures. The image improvements achieved with the diffraction-enhanced imaging technique are due to extinction, i.e., elimination of ultra-small-angle scattering. They enabled us to identify a few embedded internal shell features, such as the origin of the apex, which is the firmly attached region of the soft tissue connecting the umbilicus to the external morphology. Diffraction-enhanced imaging can provide high-quality images of soft tissues valuable for biology.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2010.04.001DOI Listing

Publication Analysis

Top Keywords

diffraction-enhanced imaging
16
soft tissues
12
soft tissue
12
synchrotron-based diffraction-enhanced
8
imaging technique
8
animal soft
8
soft
6
imaging
5
imaging visualization
4
visualization soft
4

Similar Publications

Superimposed Wavefront Imaging of Diffraction-enhanced X-rays: sparsity-aware CT reconstruction from limited-view projections.

Int J Comput Assist Radiol Surg

December 2024

High Energy Accelerator Research Organization, Tsukuba, Ibaraki, 305-0801, Japan.

Purpose: In this paper, we describe an algebraic reconstruction algorithm with a total variation regularization (ART + TV) based on the Superimposed Wavefront Imaging of Diffraction-enhanced X-rays (SWIDeX) method to effectively reduce the number of projections required for differential phase-contrast CT reconstruction.

Methods: SWIDeX is a technique that uses a Laue-case Si analyzer with closely spaced scintillator to generate second derivative phase-contrast images with high contrast of a subject. When the projections obtained by this technique are reconstructed, a Laplacian phase-contrast tomographic image with higher sparsity than the original physical distribution of the subject can be obtained.

View Article and Find Full Text PDF

The rapid acquisition of projective images with low radiation dose is essential in computed tomography with diffraction enhanced imaging to extract absorption, refraction, and scattering images from weakly absorbing specimens. This plays a critical role in applying diffraction enhanced imaging to biological and medical imaging. In this study, an improved diffraction enhanced imaging method is proposed to rapidly implement X-ray trimodal computed tomography.

View Article and Find Full Text PDF
Article Synopsis
  • Phase-contrast computed tomography (CT) using synchrotron-generated x-rays allows for high-contrast, 3D imaging of soft tissues, but traditional methods suffer from spatial resolution issues due to the required distance between the specimen and the x-ray camera.
  • The new technique, Superimposed Wavefront Imaging of Diffraction-enhanced x-rays (SWIDeX), uses a unique setup to eliminate this distance, resulting in superior spatial resolution compared to conventional methods.
  • The effectiveness of SWIDeX was demonstrated by visualizing internal structures of various human tissues, which showed clearer 3D images when compared to traditional pathological techniques.
View Article and Find Full Text PDF

In this study, we observed natural methane (CH4) hydrate sediments, which are a type of unconventional natural gas resources, using x-ray computed tomography (CT). Because CH4 hydrates are formed by hydrogen bonding of water molecules with CH4, material decomposition becomes challenging when CH4 hydrates coexist with liquid or solid water in natural sediments. Tri-contrast (absorption, refraction, and scattering) imaging was performed via diffraction enhanced x-ray CT optics using monochromatic synchrotron x rays.

View Article and Find Full Text PDF

Si/Organic Integrated Narrowband Near-Infrared Photodetector.

Small

November 2023

Tsinghua-Berkeley Shenzhen Institute (TBSI), Tsinghua University, Shenzhen, 518055, China.

Spectrally selective narrowband photodetection is critical for near-infrared (NIR) imaging applications, such as for communicationand night-vision utilities. It is a long-standing challenge for detectors based on silicon, to achieve narrowband photodetection without integrating any optical filters. Here, this work demonstrates a NIR nanograting Si/organic (PBDBT-DTBT:BTP-4F) heterojunction photodetector (PD), which for the first time obtains the full-width-at-half-maximum (FWHM) of only 26 nm and fast response of 74 µs at 895 nm.