Background: The 6-min walking test (6-MWT) is probably the most widely used test to measure the functional capacity in cardiac rehabilitation. Although the American Thoracic Society recommends testing on a flat surface, treadmills are also used for testing. Therefore, we want to investigate the interchangeability of results of treadmill and hallway 6-MWT in a population of patients participating in a cardiac rehabilitation programme.

Design: Preexperimental design.

Setting: University hospital Department of Cardiology and Physiotherapy.

Participants: Patients entering the cardiac rehabilitation programme of the Maastricht University Cardiology Department.

Main Outcome Measure: Agreement in 6-min walking distance between the hallway and treadmill test results were calculated by taking the mean difference between the two methods and the 95% confidence interval of the difference and plotting this against the average of the two test results. A Bland and Altman plot was constructed, showing the mean difference and the 95% limits of agreement between the two methods.

Results: Sixty-nine patients participated in this study. Mean difference between walking on a treadmill and walking in a hallway was 9 m in favour of the hallway test. The 95% limits of agreement were±118 m.

Conclusion: Results of the 6-MWT conducted in a hallway or on a treadmill are not interchangeable, because of large between-test variations in the distances walked by individual participants.

Download full-text PDF

Source
http://dx.doi.org/10.1097/HJR.0b013e32833a1963DOI Listing

Publication Analysis

Top Keywords

hallway treadmill
12
cardiac rehabilitation
12
walking test
8
6-min walking
8
95% limits
8
limits agreement
8
test
6
hallway
6
treadmill
5
six-minute walking
4

Similar Publications

Background: Understanding the factors that influence walking is important as quantitative walking assessments have potential to inform health risk assessments. Wearable technology innovation has enabled quantitative walking assessments to be conducted in different settings. Understanding how different settings influence quantitative walking performance is required to better utilize the health-related potential of quantitative walking assessments.

View Article and Find Full Text PDF

The six-minute walk test (6MWT) is a well-established tool for assessing submaximal functional capacity for cardiac patients, but space limitations challenge its implementation. Treadmill-based (TR) 6MWT is a promising alternative, but it requires patients to complete a familiarization test to adapt treadmill speed regulation. With the advancement of sensors, it is possible to automatically control speed for individual patients and thus overcome the space limitation or the speed control difficulty on the treadmill for each patient.

View Article and Find Full Text PDF

Cardiopulmonary response during incremental shuttle walking test in a hallway versus on treadmill in Phase IV cardiac rehabilitation: a cross-sectional study.

Sci Rep

August 2023

Department of Physical Therapy and Health Rehabilitation, College of Applied Medical Sciences, Prince Sattam Bin Abdulaziz University, Alkharj, Saudi Arabia.

There is widespread use of incremental shuttle walking test (ISWT) to measure functional capacity in cardiac rehabilitation patients. Due to occasional physical space limitations, an incremental shuttle walking test on a treadmill (ISWT-T) was suggested as an alternative. Knowledge about the cardiopulmonary response between the two tests and the factors associated with the distance achieved in Phase IV cardiac rehabilitation is limited.

View Article and Find Full Text PDF

Age and walking conditions differently affect domains of gait.

Hum Mov Sci

June 2023

University of Groningen, University Medical Center Groningen, Department of Human Movement Sciences, Groningen, the Netherlands. Electronic address:

Introduction: Analysing gait in controlled conditions that resemble daily life walking could overcome the limitations associated with gait analysis in uncontrolled real-world conditions. Such analyses could potentially aid the identification of a walking condition that magnifies age-differences in gait. Therefore, the aim of the current study was to determine the effects of age and walking conditions on gait performance.

View Article and Find Full Text PDF

Background: The use of sensory and mechanical perturbations applied during walking has grown in popularity due to their ability to elicit instability relevant to falls. However, the vast majority of perturbation studies on walking balance are performed on a treadmill at a fixed speed.

Research Question: The aim of this study was to quantify the effects of mediolateral optical flow perturbations on walking speed and balance outcomes in young adults walking with fixed-speed and self-paced treadmill controllers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!