AI Article Synopsis

  • Recent studies have explored the mechanical properties of skin, noting that traditional methods can't fully capture its complex nature, particularly its anisotropy.
  • A new experiment utilizing a force-sensitive micro-robot was conducted on human skin, revealing that its mechanical response is nonlinear, anisotropic, and viscoelastic, with significant variation based on arm orientation.
  • A finite element model was developed, accurately simulating the skin's mechanical behavior across different areas with a maximum error-of-fit of 17.5%, indicating that more advanced models are needed for precise simulations compared to neo-Hookean models.

Article Abstract

The complex mechanical properties of skin have been the subject of much study in recent years. Several experimental methods developed to measure the mechanical properties of skin in vivo, such as suction or torsion, are unable to measure skin's anisotropic characteristics. An experiment characterising the mechanical properties of in vivo human skin using a novel force-sensitive micro-robot is presented. The micro-robot applied in-plane deformations to the anterior forearm and the posterior upper arm. The behaviour of the skin in each area is highly nonlinear, anisotropic, and viscoelastic. The response of the upper arm skin is very dependent on the orientation of the arm. A finite element model consisting of an Ogden strain energy function and quasi-linear viscoelasticity was developed to simulate the experiments. An orthogonal initial stress field, representing the in vivo skin tension, was used as an additional model parameter. The model simulated the experiments accurately with an error-of-fit of 17.5% for the anterior lower forearm area, 6.5% for the anterior upper forearm and 9.3% for the posterior upper arm. The maximum in vivo tension in each area determined by the model was 6.2 Nm(-1) in the anterior lower forearm, 11.4 Nm(-1) in anterior upper forearm and 5.6 Nm(-1) in the posterior upper arm. The results also show that a finite element model with a neo-Hookean strain energy function cannot simulate the experiments with the same accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10237-010-0216-8DOI Listing

Publication Analysis

Top Keywords

upper arm
16
finite element
12
mechanical properties
12
posterior upper
12
vivo human
8
human skin
8
force-sensitive micro-robot
8
properties skin
8
arm finite
8
element model
8