Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The 4-second exercise test (T4s) evaluates the cardiac vagal tone during the initial heart rate (HR) transient at sudden dynamic exercise, through the identification of the cardiac vagal index (CVI) obtained from the electrocardiogram (ECG).
Objective: To evaluate the use of the Polar S810 heart rate monitor (HRM) as an alternative resource to the use of the electrocardiogram in the 4-second exercise test.
Methods: In this study, 49 male individuals (25 +/- 20 years, 176 +/-12 cm, 74 +/- 6 kg) underwent the 4-second exercise test. The RR intervals were recorded simultaneously by ECG and HRM. We calculated the mean and the standard deviation of the last RR interval of the pre-exercise period, or of the first RR interval of the exercise period, whichever was longer (RRB), of the shortest RR interval of the exercise period (RRC), and of the CVI obtained by ECG and HRM. We used the Student t-test for dependent samples (p < or 0.05) to test the significance of the differences between means. To identify the correlation between the ECG and the HRM, we used the linear regression to calculate the Pearson's correlation coefficient and the strategy proposed by Bland and Altman.
Results: Linear regression showed r(2) of 0.9999 for RRB, 0.9997 for RRC, and 0.9996 for CVI. Bland e Altman strategy presented standard deviation of 0.92 ms for RRB, 0.86 ms for RRC, and 0.002 for CVI.
Conclusion: Polar S810 HRM was more efficient in the application of T4s compared to the ECG.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1590/s0066-782x2010005000037 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!