In the past decade, several investigators have reported that implants inserted in autografts in the same operation (ie, simultaneously inserted implants [SIIs]) have achieved excellent results. However, no report regarding SIIs placed in fresh frozen bone (FFB) is available. Thus, the authors planned a retrospective study on a series of SIIs placed in homologue FFB (but not immediately loaded) to evaluate their clinical outcome. In addition, a comparison with implants inserted in FFB in a second stage (ie, delayed inserted implants) was performed. Seventeen patients were grafted with FFB, and 48 implants were inserted in the same operation. Implant diameter and length ranged from 3.25 to 4.0 mm and from 10.0 to 15 mm, respectively. Data were compared with 302 implants inserted in FFB in a second operation during the same period in 64 patients. Analyzing SIIs, it was noted that only 3 implants were lost (ie, survival rate [SVR] = 93.7%), and no differences were detected among the studied variables by using lost implants as a predictor of clinical outcome. On the contrary, by using crestal bone resorption around the implant's neck and specific cutoff values, it was possible to demonstrate that prosthetic restoration (ie, removable overdentures) correlated with a statistically significant lower delta insertion abutment junction (ie, reduced crestal bone loss) and thus with a better clinical outcome. By comparing SIIs with implants inserted in a second stage in FFB, a better outcome for delayed implants was demonstrated. Implants inserted simultaneously with FFB grafts had a high survival and success rate. SIIs inserted in FFB can be considered reliable devices, although a higher marginal bone loss is to be expected when fixed prosthetic restorations are used. Implants inserted in a second surgical stage have a better SVR and success rate than SIIs.

Download full-text PDF

Source
http://dx.doi.org/10.1563/AAID-JOI-D-09-00025DOI Listing

Publication Analysis

Top Keywords

implants inserted
28
implants
12
clinical outcome
12
inserted ffb
12
inserted
10
retrospective study
8
inserted implants
8
ffb
8
ffb second
8
second stage
8

Similar Publications

Background: The incidence of revision shoulder arthroplasty continues to rise, and infection is a common indication for revision surgery. Treatment of periprosthetic joint infection (PJI) in the shoulder remains a controversial topic, with the literature reporting varying methodologies, including the use of debridement and implant retention, single-stage and 2-stage surgeries, antibiotic spacers, and resection arthroplasty. Single-stage revision has been shown to have a low rate of recurrent infection, making it more favorable because it precludes the morbidity of a 2-stage operation.

View Article and Find Full Text PDF

Background And Purpose:  This study updates 2 parallel systematic reviews and meta-analyses from 2012, which established the 1-year radiostereometric (RSA) migration thresholds for tibial components of total knee replacements (TKR) based on the risk of late revision for aseptic loosening from survival studies. The primary aim of this study was to determine the (mis)categorization rate of the 2012 thresholds using the updated review as a validation dataset. Secondary aims were evaluation of 6-month migration, mean continuous (1- to 2-year) migration, and fixation-specific thresholds for tibial component migration.

View Article and Find Full Text PDF

Clinical applications of 3D printing in spine surgery: a systematic review.

Eur Spine J

January 2025

In Silico Biomechanics Laboratory, National Center for Spinal Disorders, Buda Health Center, Budapest, Hungary.

Purpose: The objective of this systematic review is to present a comprehensive summary of existing research on the use of 3D printing in spinal surgery.

Methods: The researchers conducted a thorough search of four digital databases (PubMed, Web of Science, Scopus, and Embase) to identify relevant studies published between January 1999 and December 2022. The review focused on various aspects, including the types of objects printed, clinical applications, clinical outcomes, time and cost considerations, 3D printing materials, location of 3D printing, and technologies utilized.

View Article and Find Full Text PDF

Purpose: Pressure resistance characteristics of the Paul glaucoma implant (PGI) and Ahmed ClearPath 250 (ACP), with and without the insertion of polypropylene thread in their tubes, were evaluated.

Methods: The in vitro flow pressure was evaluated at varying flow rates, both with and without threads (6-0 for PGI and 4-0 or 3-0 for ACP). Cross-sectional areas of the tube lumen and thread were measured to calculate pressure resistance using the Hagen-Poiseuille equation.

View Article and Find Full Text PDF

Intramedullary nail fixation is a routine procedure for treatment of intertrochanteric fractures. Aseptic technique is vital for reducing postoperative complications, as intraoperative glove perforations increase the risk of surgical site infections. The aim of this study was to determine the incidence of surgical glove perforation during intramedullary nailing of intertrochanteric fractures and to identify surgery-specific steps at risk.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!