A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biomechanical evaluation of the fixation methods for transcondylar fracture of the humerus:ONI plate versus conventional plates and screws. | LitMetric

We biomechanically evaluated the bone fixation rigidity of an ONI plate (Group I) during fixation of experimentally created transcondylar humerus fractures in cadaveric elbows, which are the most frequently observed humeral fractures in the elderly, and compared it with the rigidity achieved by 3 conventional fixation methods:an LCP reconstruction plate 3.5 using a locking mechanism (Group II), a conventional reconstruction plate 3.5 (CRP) with a cannulated cancellous screw (Group III), and a CRP with 2 cannulated cancellous screws (CS) in a crisscross orientation (Group IV). In the axial loading test, the mean failure loads were:Group I, 98.9+/-32.6;Group II, 108.5+/-27.2;Group III, 50.0+/-7.5;and Group IV, 34.5+/-12.2 (N). Group I fixations failed at a significantly higher load than those of Groups III and IV (p<0.05). In the extension loading test, the mean failure loads were:Group I, 34.0+/-12.4;Group II, 51.0+/-14.8;Group III, 19.3+/-6.0;and Group IV, 14.7+/-3.1 (N). Group IV fixations showed a significantly lower failure load than those of Group I (p<0.05). The fixation rigidities against mechanical loading by the ONI plate and LCP plate were comparable. These results suggested that an ONI system might be superior to the CRP and CS method, and comparable to the LCP method in terms of fixation rigidity for distal humerus fractures.

Download full-text PDF

Source
http://dx.doi.org/10.18926/AMO/32855DOI Listing

Publication Analysis

Top Keywords

reconstruction plate
8
crp cannulated
8
cannulated cancellous
8
group
6
biomechanical evaluation
4
fixation
4
evaluation fixation
4
fixation methods
4
methods transcondylar
4
transcondylar fracture
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!