Distribution characteristics of airborne bacteria and fungi in the general hospitals of Korea.

Ind Health

Institute of Industrial and Environmental Medicine, Hanyang University, Seoul, Republic of Korea.

Published: July 2010

The objective of this study is to provide fundamental data related to size-based characteristics of bioaerosol distributed in the general hospital. Measurement sites are main lobby, ICU, surgical ward and biomedical laboratory and total five times were sampled with six-stage cascade impactor. Mean concentrations of airborne bacteria and fungi were the highest in main lobby as followed by an order of surgical ward, ICU and biomedical laboratory. The predominant genera of airborne bacteria identified in the general hospital were Staphylococcus spp. (50%), Micrococcus spp. (15-20%), Corynebacterium spp. (5-20%), and Bacillus spp. (5-15%). On the other hand, the predominant genera of airborne fungi identified in the general hospital were Cladosporium spp. (30%), Penicillium spp. (20-25%), Aspergillus spp. (15-20%), and Alternaria spp. (10-20%). The detection rate was generally highest on stage 5 (1.1-2.1 microm) for airborne bacteria and on stage 1 (>7.0 microm) for airborne fungi.

Download full-text PDF

Source
http://dx.doi.org/10.2486/indhealth.48.236DOI Listing

Publication Analysis

Top Keywords

airborne bacteria
16
general hospital
12
bacteria fungi
8
main lobby
8
surgical ward
8
biomedical laboratory
8
predominant genera
8
genera airborne
8
identified general
8
spp
8

Similar Publications

SARS-CoV-2 infection is accompanied by elevated liver enzymes, and patients with pre-existing liver conditions experience more severe disease. While it was known that SARS-CoV-2 infects human hepatocytes, our study determines the mechanism of infection, demonstrates viral replication and spread, and highlights direct hepatocyte damage. Viral replication was readily detectable upon infection of primary human hepatocytes and hepatoma cells with the ancestral SARS-CoV-2, Delta, and Omicron variants.

View Article and Find Full Text PDF

Bioaerosols significantly influence air quality and human health. This study investigated the diversity, structure, and interaction of bacterial communities in particulate matter (PM) across four seasons in Xi'an. The results revealed that operational taxonomic units (OTUs) were the highest in autumn, reaching levels comparable to those in winter, but were 3.

View Article and Find Full Text PDF

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza A virus are primarily transmitted through droplets or aerosols from patients. The inactivation effects of existing virus control techniques may vary depending on the environmental factors. Therefore, it is important to establish a suitable evaluation system for assessing virus control techniques against airborne viruses for further real-world implementation.

View Article and Find Full Text PDF
Article Synopsis
  • Fungal contamination in hospital air can impact the health of staff, patients, and caregivers, with a study in Wuhan revealing that factors like temperature, humidity, and seasonal changes significantly influence fungal concentration rather than disease type or personnel density.
  • The analysis showed that airborne fungal particle sizes are normally distributed, with the highest proportions found in specific size ranges, but the median diameter remained below 3.19 μm across different departments in both winter and summer.
  • The findings suggest a need for improved filtration efficiency for specific fungal particle sizes and the use of appropriate antifungal treatments and hygiene practices in hospital air management.
View Article and Find Full Text PDF

Respiratory interventions including noninvasive ventilation, continuous positive airway pressure and high-flow nasal oxygen generated infectious aerosols may increase risk of airborne disease (SARS-CoV-2, influenza virus) transmission to healthcare workers. We developed and tested a prototype portable UV-C device to sterilize high flows of viral-contaminated air from a simulated patient source at airflow rates of up to 100 l/m. Our device consisted of a central quartz tube surrounded 6 high-output UV-C lamps, within a larger cylinder allowing recirculation past the UV-C lamps a second time before exiting the device.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!