Novel hydrogel-based preparation-free EEG electrode.

IEEE Trans Neural Syst Rehabil Eng

Bioengineering Department, University of Pittsburgh, Pittsburgh, PA 15260, USA.

Published: August 2010

The largest obstacles to signal transduction for electroencephalography (EEG) recording are the hair and the epidermal stratum corneum of the skin. In typical clinical situations, hair is parted or removed, and the stratum corneum is either abraded or punctured using invasive penetration devices. These steps increase preparation time, discomfort, and the risk of infection. Cross-linked sodium polyacrylate gel swelled with electrolyte was explored as a possible skin contact element for a prototype preparation-free EEG electrode. As a superabsorbent hydrogel, polyacrylate can swell with electrolyte solution to a degree far beyond typical contemporary electrode materials, delivering a strong hydrating effect to the skin surface. This hydrating power allows the material to increase the effective skin contact surface area through wetting, and noninvasively decrease or bypass the highly resistive barrier of the stratum corneum, allowing for reduced impedance and improved electrode performance. For the purposes of the tests performed in this study, the polyacrylate was prepared both as a solid elastic gel and as a flowable paste designed to penetrate dense scalp hair. The gel can hold 99.2% DI water or 91% electrolyte solution, and the water content remains high after 29 h of air exposure. The electrical impedance of the gel electrode on unprepared human forearm is significantly lower than a number of commercial ECG and EEG electrodes. This low impedance was maintained for at least 8 h (the longest time period measured). When a paste form of the electrode was applied directly onto scalp hair, the impedance was found to be lower than that measured with commercially available EEG paste applied in the same manner. Time-frequency transformation analysis of frontal lobe EEG recordings indicated comparable frequency response between the polyacrylate-based electrode on unprepared skin and the commercial EEG electrode on abraded skin. Evoked potential recordings demonstrated signal-to-noise ratios of the experimental and commercial electrodes to be effectively equivalent. These results suggest that the polyacrylate-based electrode offers a powerful option for EEG recording without scalp preparation.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TNSRE.2010.2048579DOI Listing

Publication Analysis

Top Keywords

eeg electrode
12
stratum corneum
12
electrode
9
eeg
8
preparation-free eeg
8
eeg recording
8
skin contact
8
electrolyte solution
8
scalp hair
8
electrode unprepared
8

Similar Publications

Refining computer-assisted SEEG planning with spatial priors - A novel comparison of implantation strategies across adult and paediatric centres.

Neurophysiol Clin

January 2025

Developmental Neurosciences, UCL Great Ormond Street Institute of Child Health, London, WC1N 1EH, UK; Department of Neurosurgery, Great Ormond Street Hospital for Children, London, WC1N 3JH, UK.

Objectives: Computer-assisted planning (CAP) allows faster SEEG planning and improves grey matter sampling, orthogonal drilling angles to the skull, reduces risk scores and minimises intracerebral electrode length. Incorporating prior SEEG trajectories enhances CAP planning, refining output with centre-specific practices. This study significantly expands on the previous work, compares priors libraries between two centres, and describes differences between SEEG in adults and children in these centres.

View Article and Find Full Text PDF

Speech production engages a distributed network of cortical and subcortical brain regions. The supplementary motor area (SMA) has long been thought to be a key hub in coordinating across these regions to initiate voluntary movements, including speech. We analyzed direct intracranial recordings from 115 patients with epilepsy as they articulated a single word in a subset of trials from a picture-naming task.

View Article and Find Full Text PDF

Diagnostic accuracy of reduced electroencephalography montages for seizure detection: A frequentist and Bayesian meta-analysis.

Neurophysiol Clin

January 2025

School of Public Health, College of Public Health, Taipei Medical University, Taipei, Taiwan; Department of Emergency Medicine, Taipei Medical University Hospital, Taipei, Taiwan; Department of Public Health, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan; Center of Evidence-Based Medicine, Taipei Medical University Hospital, Taipei, Taiwan; Department of Medical Research, Taipei Medical University Hospital, Taipei, Taiwan. Electronic address:

Aim: To evaluate the diagnostic accuracy of reduced montage electroencephalography (EEG) for seizure detection and provide evidence-based recommendations.

Methods: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, we conducted a diagnostic meta-analysis to assess the sensitivity and specificity of reduced EEG montages in detecting seizure activity. A hierarchical summary receiver operating characteristic curve (HSROC) model was used to estimate the area under the curve (AUC).

View Article and Find Full Text PDF

The human visual system is tuned to symmetry, and the neural response to visual symmetry has been well studied. One line of research measures an Event Related Potential (ERP) component called the Sustained Posterior Negativity (SPN). Amplitude is more negative at posterior electrodes when participants see symmetrical patterns compared to asymmetrical patterns.

View Article and Find Full Text PDF

Skin-like bioelectronics offer a transformative technological frontier, catering to continuous and real-time yet highly imperceptible and socially discreet digital healthcare. The key technological breakthrough enabling these innovations stems from advancements in novel material synthesis, with unparalleled possibilities such as conformability, miniature footprint, and elasticity. However, existing solutions still lack desirable properties like self-adhesivity, breathability, biodegradability, transparency, and fail to offer a streamlined and scalable fabrication process.

View Article and Find Full Text PDF