Recently, we reported on the axial-shear strain fill-in of the interior of loosely bonded stiff elliptical inclusions in a soft background at non-normal orientations, and the lack of fill-in in firmly bonded inclusions at any orientation. In this paper, we report on the experimental validation of the simulation studies using tissue-mimicking gelatin-based phantoms. We also show a few confirmatory examples of the existence of these phenomena in benign vs. malignant breast lesions in vivo. Phantom experiments showed that axial-shear strain zones caused by firmly bonded elliptical inclusions occurred only outside of the inclusion, as predicted by the simulation. By contrast, the axial-shear strain zones filled in the interior of loosely bonded elliptical inclusions at non-normal orientations. The axial-shear strain elastograms obtained from the in vivo cases appeared to be in general agreement with our experimental results. The results reported in this paper may have important clinical implications. Specifically, axial-shear strain fill-in inside an inclusion may be a unique signature of stiff, loosely bonded, ellipsoidal or elongated inclusions at non-normal orientations. Thus, it may be useful as a marker of benignity of benign breast lesions (e.g., fibroadenomas) that are generally stiff, elongated and loosely bonded to the host tissues.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2010.02.004DOI Listing

Publication Analysis

Top Keywords

axial-shear strain
24
loosely bonded
16
elliptical inclusions
12
non-normal orientations
12
experimental validation
8
strain fill-in
8
interior loosely
8
firmly bonded
8
breast lesions
8
strain zones
8

Similar Publications

Energy-based displacement tracking of ultrasound images can be implemented by optimizing a cost function consisting of a data term, a mechanical congruency term, and first- and second-order continuity terms. This approach recently provided a promising solution to two-dimensional axial and lateral displacement tracking in ultrasound strain elastography. However, the associated second-order regularizer only considers the unmixed second derivatives and disregards the mixed derivatives, thereby providing suboptimal noise suppression and limiting possibilities for total strain tensor imaging.

View Article and Find Full Text PDF

Enhancing clayey soil performance with lime and waste rubber tyre powder: Mechanical, microstructural, and statistical analysis.

Environ Res

September 2024

Interdisciplinary Research Center for Sustainable Energy Systems (IRC-SES), Research Institute, King Fahd University of Petroleum & Minerals, Dhahran, 31261, Saudi Arabia.

Nowadays, for soil stabilisation and cleaner production of geo-composites, the possibility of utilizing waste rubber is in vogue. The present paper deals with experimentally investigating the mechanical and micro-structural characteristics of weak Indian clayey soil partially substituted with lime (0-3.5%) and waste rubber tyre powder (0-15%).

View Article and Find Full Text PDF

Finite element (FE) models of the human head are valuable instruments to explore the mechanobiological pathway from external loading, localized brain response, and resultant injury risks. The injury predictability of these models depends on the use of effective criteria as injury predictors. The FE-derived normal deformation along white matter (WM) fiber tracts (i.

View Article and Find Full Text PDF

Importance of the Ultrasound Probe Angle on the Rotation Fill-in Signature in Ultrasound Axial-Shear Strain Imaging.

Ultrasound Med Biol

February 2021

Instituto de Fisica de Buenos Aires (IFIBA-CONICET), Departamento de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Ciudad Universitaria, Buenos Aires, Argentina.

The rotation fill-in is a signature of tumor benignity in rotation elastograms and has been used for breast tumor classification. It is a consequence of the bonding condition at the tumor-tissue interface. In vivo studies have revealed the presence of fluctuations when inclined uniaxial external compression is applied.

View Article and Find Full Text PDF

A biomechanical study on the laminate stacking sequence in composite bone plates for vancouver femur B1 fracture fixation.

Comput Methods Programs Biomed

November 2020

Department of Mechanical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamilnadu-603203, India. Electronic address:

Background And Objectives: Composite bone plates are proposed for fracture fixation in periprosthetic femoral fracture. Metallic plates, having high stiffness compared to bone lead to stress shielding, reduce the compression force in the fracture site, affectthe healing process. Reduction of stiffness in the axial direction due to above reason without lowering the stiffness in transverse to avoid much of shear strain and thus avoiding instability at the fracture site leads to selective stress shielding.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?