Background: Measurement of functional residual capacity (FRC) is now possible at bedside, during mechanical ventilation.

Objectives: To determine the relationship of measured absolute and relative predicted FRC values to oxygenation and respiratory-system compliance, and to identify variables that influence FRC in ventilated patients after cardiac surgery.

Methods: We retrospectively analyzed data from 99 patients ventilated after cardiac surgery. Each patient underwent an alveolar recruitment maneuver and was then ventilated with a positive end-expiratory pressure of 10 cm H2O and a tidal volume of 6-8 mL/kg predicted body weight. We measured quasi-static 2-point compliance of the respiratory system, FRC (with the oxygen-wash-out method), PaO2, and fraction of inspired oxygen (F(I)O2). We indexed the FRC values to predicted FRC reference values from sitting and supine healthy volunteers.

Results: Correlation analyses revealed no meaningful association between FRC and PaO2/F(I)O2 (r2 0.20, P < .001). There was a moderate association between absolute FRC and respiratory-system compliance (r2 0.50, P < .001). Indexing the absolute measured FRC values to the predicted FRC values did not improve the correlation. We conducted multiple linear regression analyses of height, weight, age, sex, presence of mild chronic obstructive pulmonary disease, minute volume, and peak inspiratory pressure during ventilation, and revealed weight, minute volume, and peak inspiratory pressure (r2 = 0.65) as independent covariates of FRC.

Conclusions: Indexing the measured FRC values to the predicted supine and sitting FRC values does not improve the association between PaO2/F(I)O2 and respiratory-system compliance. In mechanically ventilated patients after cardiac surgery, FRC is influenced more by the ventilator settings than by physiologic variables (as in spontaneously breathing persons).

Download full-text PDF

Source

Publication Analysis

Top Keywords

frc values
24
frc
13
cardiac surgery
12
predicted frc
12
respiratory-system compliance
12
values predicted
12
functional residual
8
residual capacity
8
patients ventilated
8
ventilated cardiac
8

Similar Publications

For the first time asymmetric and symmetric carboxytriazoleimidazolium derivatives with different structures were synthesized. The critical micellization concentration (CMC) value was estimated using a pyrene fluorescent probe and the solubility of Orange OT. The complexation ability of carboxytriazoleimidazolium derivatives toward bovine serum albumin (BSA) has been investigated by various physico-chemical methods: fluorescence spectroscopy, electrophoretic light scattering and circular dichroism.

View Article and Find Full Text PDF

Selective breeding is a potent method for developing strains with enhanced traits. This study compared the growth performance and stress responses of the genetically improved Abbassa Nile tilapia strain (G9; GIANT-G9) with a local commercial strain over 12 weeks, followed by exposure to stressors including high ammonia (10 mg TAN/L), elevated temperature (37 °C), and both for three days. The GIANT-G9 showed superior growth, including greater weight gain, final weight, length gain, specific growth rate, and protein efficiency ratio, as well as a lower feed conversion ratio and condition factor compared to the commercial strain.

View Article and Find Full Text PDF

Alzheimer's disease (AD) poses a significant public health issue. Despite the fact that today there are several methods of maintenance therapy, one of the most widely used methods is designed to correct the deficiency of acetylcholine. In the search for new potential inhibitors of cholinesterase enzymes, eight new derivatives of 3-oxo- or 2,3-indolo-triterpenic acid conjugated with amino-quinuclidine bicyclic cores were designed and synthesized.

View Article and Find Full Text PDF

Background: Long-term durability of a restoration relies on the marginal integrity and its ability to withstand the occlusal forces. Fiber-reinforced composites (FRCs) exhibited superior properties in terms of fracture toughness, flexural strength, and wear resistance.

Aim: The aim of this study was to assess and compare marginal adaptation and microtensile bond strength (µTBS) of posterior FRCs comparing with a condensable composite.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!