A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Efficacy of bougie in difficult intubation with the Airway Scope caused by inability to lift the epiglottis directly]. | LitMetric

Background: There are some disadvantages of the Airway Scope (AWS), and the most crucial one is that the AWS has only one fixed-size AWS blade. When the blade is too short to reach beneath the epiglottis and to lift it directly, an endotracheal tube hits the epiglottis and cannot be advanced into the glottic aperture even when it is visible. A bougie may solve this difficulty because its angulated tip can be controlled in a desired direction. Therefore, we examined the efficacy of the bougie on this problem.

Methods: Forty patients were randomly classified into two groups: intubation with only the AWS, and with the AWS and the bougie. After general anesthesia and muscle relaxation, the AWS blade tip was positioned in the vallecula, the glottis was fully exposed, and intubation using the AWS with or without a bougie was performed. Success rate and time to intubation were compared in both groups.

Results: Success rate was 13/20 in intubation with only the AWS and 19/20 in intubation with the AWS and the bougie (P<0.05). Median intubation time was reduced from 48 sec without the bougie to 29 sec with the bougie (P<0.01).

Conclusions: Use of the bougie was useful for difficult intubation with the AWS caused by inability to lift the epiglottis directly.

Download full-text PDF

Source

Publication Analysis

Top Keywords

intubation aws
16
aws bougie
12
aws
9
airway scope
8
aws blade
8
success rate
8
intubation
6
bougie
5
[efficacy bougie
4
bougie difficult
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!