Aim: We explored the feasibility of renal artery multidetector computed tomography (MDCT) and detection of in-stent restenosis at low exposure settings.

Patients/methods: Sixteen patients with 19 renal artery stents underwent CT angiography. A biphasic protocol was performed including arteriographic acquisition at standard 120 kVp and a late-arterial scan at 100 kVp (n=9) or 80 kVp (n=7). Images were reconstructed under various algorithms. Signal-to-noise and contrast-to-noise ratios (SNR, CNR) were determined within stent, aorta and renal arteries. Image quality and the presence of restenosis were assessed. Volume CT dose-index was recorded and dose reduction (DR%) between phases was calculated.

Results: Ten patients presented with Hounsfield values >250 HU in all segments, phases and reconstructions and were further evaluated. The 120 kVp protocol performed better in all vessels and reconstruction algorithms. SNR at 120 kVp (B31f) did not differ significantly compared to 100 kVp (B31f). CNR within stent was borderline compromised at 100 kVp (p=0.042). All but two image sets (at 80 kVp) were considered diagnostic. Minor loss of subjective image quality was noticed at 100 kVp. No difference in assessment of restenosis was observed between 120 kVp and the diagnostic low-exposure scans. Mean DR% was estimated 45% at 100 kVp and 77% at 80 kVp.

Conclusions: Renal MDCT angiography and stent-restenosis assessment are feasible at 100 kVp with minor loss of image quality and almost half radiation exposure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2010.03.017DOI Listing

Publication Analysis

Top Keywords

100 kvp
24
120 kvp
16
renal artery
12
kvp
12
image quality
12
mdct angiography
8
in-stent restenosis
8
radiation exposure
8
protocol performed
8
kvp b31f
8

Similar Publications

Intraindividual Comparison of Image Quality Between Low-Dose and Ultra-Low-Dose Abdominal CT With Deep Learning Reconstruction and Standard-Dose Abdominal CT Using Dual-Split Scan.

Invest Radiol

January 2025

From the Department of Radiology, Ulsan University Hospital, Ulsan, Republic of Korea (T.Y.L.); Department of Radiology, University of Ulsan College of Medicine, Seoul, Republic of Korea (T.Y.L.); Department of Radiology, Seoul National University Hospital, Seoul, Republic of Korea (J.H.Y., H.K., J.M.L.); Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea (J.H.Y., S.H.P., J.M.L.); Department of Radiology, Inje University Busan Paik Hospital, Busan, Republic of Korea (J.Y.P.); Department of Radiology, Seoul National University Bundang Hospital, Seongnam, Republic of Korea (S.H.P.); Department of Radiology, Hanyang University College of Medicine, Seoul, Republic of Korea (C.L.); Division of Biostatistics, Medical Research Collaborating Center, Seoul National University Hospital, Seoul, Republic of Korea (Y.C.); and Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Republic of Korea (J.M.L.).

Objective: The aim of this study was to intraindividually compare the conspicuity of focal liver lesions (FLLs) between low- and ultra-low-dose computed tomography (CT) with deep learning reconstruction (DLR) and standard-dose CT with model-based iterative reconstruction (MBIR) from a single CT using dual-split scan in patients with suspected liver metastasis via a noninferiority design.

Materials And Methods: This prospective study enrolled participants who met the eligibility criteria at 2 tertiary hospitals in South Korea from June 2022 to January 2023. The criteria included (a) being aged between 20 and 85 years and (b) having suspected or known liver metastases.

View Article and Find Full Text PDF

Evaluation of charge summing correction in CdTe-based photon-counting detectors for breast CT: performance metrics and image quality.

J Med Imaging (Bellingham)

January 2025

U.S. Food and Drug Administration, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, Silver Spring, Maryland, United States.

Purpose: We evaluate the impact of charge summing correction on a cadmium telluride (CdTe)-based photon-counting detector in breast computed tomography (CT).

Approach: We employ a custom-built laboratory benchtop system using the X-THOR FX30 0.75-mm CdTe detector (Varex Imaging, Salt Lake City, Utah, United States) with a pixel pitch of 0.

View Article and Find Full Text PDF

In abdominal X-ray examinations, radiosensitive organs such as the gonads within or near the imaging region are at risk of radiation exposure. Minimizing the dose to these organs is crucial to reducing unnecessary radiation. This study utilized optically stimulated luminescence dosimeters (OSLDs) to measure the radiation dose to the male gonads at varying kilovoltage peak (kVp) settings while keeping the milliampere-seconds (mAs) constant across different radiographic projections.

View Article and Find Full Text PDF

Objectives: To investigate the image quality and diagnostic performance with ultra-low dose dual-layer detector spectral CT (DLSCT) by various reconstruction techniques for evaluation of pulmonary nodules.

Materials And Methods: Between April 2023 and December 2023, patients with suspected pulmonary nodules were prospectively enrolled and underwent regular-dose chest CT (RDCT; 120 kVp/automatic tube current) and ultra-low dose CT (ULDCT; 100 kVp/10 mAs) on a DLSCT scanner. ULDCT was reconstructed with hybrid iterative reconstruction (HIR), electron density map (EDM), and virtual monoenergetic images at 40 keV and 70 keV.

View Article and Find Full Text PDF

Background: Craniosynostosis may result in malformations of the orbit, which can be observed in clinical presentations. Craniosynostosis impairs the normal growth of the skull, which typically occurs perpendicular to the fused suture. Craniosynostosis is classified into non-syndromic and syndromic, with an incidence of 1: 2000-2500 live births.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!